Endress+HauserProline Promag W 400
Расходомеры
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

The Prowirl D 200 is the low-cost wafer-design member of the Proline Prowirl 200 family, intended for all basic applications and as a one-to-one replacement for orifice plates.
Цена
Нет в наличии — запросите предложение на поставкуОтправьте запрос, чтобы узнать цену.



Этот раздел доступен только на английском языке

Steam metering and energy balancing for boilers, headers…

Liquids in chemical, petrochemical and general process…
One-to-one replacement of orifice plates in basic…
Gases and compressed air in utility and process lines.
Этот раздел доступен только на английском языке
The Prowirl D 200 is the low-cost wafer-design member of the Proline Prowirl 200 family, intended for all basic applications and as a one-to-one replacement for orifice plates.
Endress+Hauser Proline Prowirl D 200 Vortex Flowmeter: The Prowirl D 200 is the low-cost wafer-design member of the Proline Prowirl 200 family, intended for all basic applications and as a one-to-one replacement for orifice plates.
A vortex flowmeter places a bluff body in the flow; behind it vortices shed alternately (Karman vortex street), and their frequency is proportional to the flow velocity. The sensor detects these pressure oscillations and the transmitter converts them to volume flow, and with temperature measurement to mass or energy flow. It is a preferred principle for wet, saturated and superheated steam, gases and liquids, including cryogenic media.
Short face-to-face length of 65 mm with included centering rings and no flanges, which also keeps the weight low. Key figures from the official data: nominal diameter DN 15–150; maximum measured error ±0.75 % … ±1.00 %; measuring range 0.16–625 m³/h; medium temperature –40…+260 °C; process pressure up to PN 40 / Class 300 / 20K.
Barmaan supplies this model by order code on inquiry; there is no list price on the page. Send the nominal diameter, medium, process connection and the required outputs, and we will confirm the configuration against the official Technical Information.
| Параметр | Значение |
|---|---|
| General | |
| Measuring principle | Vortex (Karman vortex street), DSC sensor |
| Nominal diameter range | DN 15 to 150 (½ to 6") |
| Degree of protection | IP66/67, type 4X enclosure |
| Approvals and certificates | ATEX, IECEx, cCSAus, EAC; functional safety per IEC 61508; PED, CRN |
| Official document | Technical Information TI01083D |
| Performance & accuracy | |
| Maximum measured error | Volume flow: ±0.75 % (liquid), ±1.00 % (steam, gas); mass flow: ±0.85 % (liquid), ±1.7 % (steam, gas) |
| Measuring range | Liquid: 0.16 to 625 m³/h; steam, gas: 2 to 8342 m³/h (depending on medium) |
| Process conditions | |
| Medium temperature range | Standard: –40 to +260 °C; high/low temperature option: –200 to +400 °C |
| Maximum process pressure | PN 40, Class 300, 20K |
| Wetted materials | Measuring tube: 1.4408 (CF3M); DSC sensor: 1.4435 (316/316L) |
| Electrical & communication | |
| Digital communication | 4–20 mA HART; PROFIBUS PA; FOUNDATION Fieldbus; pulse/frequency/switch output |
| Power supply | DC 12 to 35 V (4–20 mA HART) |
Этот раздел доступен только на английском языке
One-to-one replacement of orifice plates in basic…

Steam metering and energy balancing for boilers, headers…
Gases and compressed air in utility and process lines.

Liquids in chemical, petrochemical and general process…
Отзывов пока нет
Будьте первым, кто оставит отзыв об этом продукте.
Этот раздел доступен только на английском языке
The Technical Information names wet, saturated and superheated steam, gases and liquids, including cryogenic media, as the preferred applications.
4–20 mA HART, PROFIBUS PA and FOUNDATION Fieldbus, plus pulse/frequency/switch output and a 4–20 mA current input.
The manufacturer lists ATEX, IECEx, cCSAus and EAC approvals and functional safety per IEC 61508; confirm the approval of your exact order code in the Technical Information.
The D 200 is the wafer design (DN 15 to 150, centering rings, 65 mm face-to-face), while the F 200 is flanged and covers DN 15 to 300 with higher flow ranges.
The official Endress+Hauser Technical Information TI01083D is attached in the downloads section of this page, so you have the full specification and ordering information.
Pricing depends on nominal diameter, process connection, materials, approvals and the transmitter configuration (order code). Send us your requirements and we quote it on request.

Расходомеры
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

Расходомеры
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Расходомеры
HART, Modbus RS485, IO-Link; 4–20 mA; pulse/frequency/switch…

Расходомеры
4–20 mA HART + Pulse/Frequency (I-OUT, f-OUT)
Отправка в течение 1 дня
от 4 000 $

Расходомеры
M-Bus, wireless M-Bus, Modbus, BACnet, LoRa … (2 module slots)

Расходомеры
LTE Cat M1, Cat NB1, Cat NB2, GPRS, EGPRS; Modbus RS485; 3x…

Расходомеры
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Расходомеры

Расходомеры
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…
Калибровка, испытания и поставка для этого оборудования