现货 5 台Endress+HauserLevel Sensors & Transmitters
本节目前仅提供英文版本
Non-contact free-space radar level transmitter for liquids, pastes and sludges, with horn or planar antenna, ±6 mm accuracy, up to +400 °C / 160 bar and SIL 3 functional safety.
The Endress+Hauser Micropilot FMR54 is a continuous, non-contact free-space radar level transmitter for liquids, pastes and sludges. Because the measurement is based on the time-of-flight of a microwave pulse reflected from the product surface, it is unaffected by changing density, temperature swings, gas blankets or vapors above the medium.
The FMR54 is the high-temperature / high-pressure member of the classic Micropilot F-series. With the appropriate seal and process separation it covers a process temperature range of –196 to +400 °C (–321 to +752 °F) and a process pressure range of –1 to +160 bar (–14.5 to +2320 psi), which makes it suitable for reactors, distillation columns, high-pressure separators and other demanding vessels. Operating in C-band (~6 GHz), it reaches a maximum measuring range of 20 m (66 ft) with a horn antenna, or 38 m (125 ft) with a planar antenna in a stilling well, at a reference accuracy of ±6 mm (0.24 in) over the entire range.
The device is offered with a horn antenna (80 to 250 mm / 3 to 10 in) or a planar antenna (150 to 300 mm / 6 to 12 in). The planar antenna is particularly suited to stilling-well applications and does not depend on the alignment or geometry of standard stilling wells. Wetted parts (horn, flange, process separation) are 316L stainless steel with PTFE or Al2O3 separation and a choice of FKM (Viton), FFKM (Kalrez), EPDM or graphite seals, so the instrument can be matched to aggressive, hot or high-pressure media.
Electronically the standard version is a 2-wire, 4–20 mA HART loop-powered transmitter; PROFIBUS PA and FOUNDATION Fieldbus versions and an optional switch output are available, together with Bluetooth commissioning through the SmartBlue app. Reliability features include Multi-Echo Tracking, HistoROM data management and Heartbeat Technology. The FMR54 carries international hazardous-area approvals (ATEX, IECEx, FM, CSA, NEPSI, INMETRO, JPN Ex), IP68/NEMA6P protection, WHG overfill prevention and functional safety up to SIL 3 (homogeneous or diverse redundancy) per IEC 61508. All figures are quoted verbatim from Endress+Hauser Technical Information TI01041F.
本节目前仅提供英文版本
本节目前仅提供英文版本
| 参数项 | 参数值 |
|---|---|
| General | |
| Measuring principle | Free-space radar, non-contact, time-of-flight (pulse) |
| Measured variable | Level of liquids, pastes and sludges (distance to product surface) |
| Performance & accuracy | |
| Operating frequency | C-band (~6 GHz) |
| Max. measuring range | Horn: 20 m (66 ft); Planar antenna in stilling well: 38 m (125 ft) |
| Max. measured error (accuracy) | ±6 mm (0.24 in) throughout the entire measuring range |
| Measured value resolution | Digital: 1 mm; Analog: 1 µA |
| Process conditions & connection | |
| Process temperature | –196 to +400 °C (–321 to +752 °F), seal-dependent |
| Process pressure | –1 to +160 bar (–14.5 to +2320 psi), seal-dependent |
| Ambient temperature | –40 to +80 °C (–40 to +176 °F); option –50 °C (–58 °F) |
| Process connection | Flanges per EN 1092-1, ASME B16.5, JIS B2220 (e.g. NPS 2–12 in Cl.150/300; DN80–DN300) |
| Construction & materials | |
| Antenna options (FMR54) | Horn 80/100/150/200/250 mm (3–10 in) or planar 150–300 mm (6–12 in) |
| Wetted materials | Horn antenna & flange: 316L (1.4404/1.4435); process separation: PTFE or Al2O3; seals: FKM/FFKM/EPDM/graphite |
| Degree of protection | IP68 / NEMA6P (closed housing); IP66 / NEMA4X |
| Power & output | |
| Output signal | 4–20 mA HART (2-wire); optional PROFIBUS PA / FOUNDATION Fieldbus; Bluetooth (SmartBlue) |
| HART protocol | HART 7.0; Manufacturer ID 17 (0x11); Device type 0x1128 |
| Supply voltage | 2-wire 4–20 mA HART: 10.4–35 VDC (non-Ex); 4-wire: 90–253 VAC or 10.4–48 VDC |
| Power consumption | 2-wire: < 0.9 W; 4-wire (VAC): 6 VA |
| Approvals & safety | |
| Explosion protection | ATEX, IECEx, FM, CSA, NEPSI, INMETRO, JPN Ex, KC |
| Functional safety | Up to SIL 3 (homogeneous or diverse redundancy) per IEC 61508 (TÜV Rheinland); SIL 2 single |
| Overfill prevention | WHG approval Z-65.16-524 |
本节目前仅提供英文版本
| 型号代码 | 说明 | 测量范围 |
|---|---|---|
| FMR51 | Micropilot FMR51Free-space radar for liquids with horn or drip-off/encapsulated antenna; general storage and process vessels. | up to 40 m |
| FMR52 | Micropilot FMR52Fully PTFE-wetted / flush-mount hygienic version for food, beverage and pharma applications. | up to 20 m |
| FMR53 | Micropilot FMR53Rod-antenna version (PTFE rod 390/540 mm) for corrosive liquids and smaller nozzles; shares TI01041F with FMR54. | up to 20 m |
| FMR54 ★ | Micropilot FMR54 (this product)High-temperature / high-pressure liquid version with horn or planar antenna; up to +400 °C, 160 bar, SIL 3. | Horn 20 m; Planar in stilling well 38 m |
| FMR56 | Micropilot FMR56Free-space radar of the F-series configured for bulk solids in silos and hoppers. | solids applications |
| FMR57 | Micropilot FMR57F-series solids radar with alignment unit / larger antenna for long-range silo and stockpile level. | solids applications |
所列全部型号均可按您所需的认证、输出协议及过程连接方式供货 — 如需确定具体型号代码,请联系我们或提交询价。
本节目前仅提供英文版本
No. Per Endress+Hauser Technical Information TI01041F, the FMR53/FMR54 operate in C-band (~6 GHz). The 80 GHz devices are the newer Micropilot FMR6x / FMRxxB series. The FMR54 is the classic free-space pulse radar for high-temperature, high-pressure liquid applications.
The horn antenna (80–250 mm) suits free-space installation in vessels and reaches up to 20 m. The planar antenna (150–300 mm) is designed for stilling wells, is independent of stilling-well alignment/geometry, and extends the range to 38 m. Horn sizes BC (80 mm) and BD (100 mm) are only for bypass/stilling-well use, not free-space.
With the graphite (HT) seal, the FMR54 covers a process temperature of –196 to +400 °C and process pressure of –1 to +160 bar. Actual limits depend on the selected antenna, seal and flange rating; CRN-approved graphite versions are limited to 100 bar.
Barmaan supplies the Micropilot FMR54 to order against an official proforma invoice. Because pricing and lead time depend on the exact configuration – antenna (feature 070), seal (090), process connection/flange (100) and communication/approval options – please share your process temperature, pressure, tank height and flange size (this unit's photos show a DN100 PN16 flange). Our team confirms the full order code and issues a proforma with delivery terms.
现货 5 台Endress+HauserLevel Sensors & Transmitters
现货 3 台RosemountLevel Sensors & Transmitters
现货 6 台Endress+HauserLevel Sensors & Transmitters
缺货Emerson / RosemountLevel Sensors & Transmitters
现货 2 台Endress+HauserLevel Sensors & Transmitters
缺货Emerson / RosemountLevel Sensors & Transmitters

Endress+HauserLevel Sensors & Transmitters
现货 2 台Endress+HauserLevel Sensors & Transmitters
现货 2 台Endress+HauserLevel Sensors & Transmitters
面向此类设备的校准、检测与供应服务