Перейти к основному содержимому
Barmaan Trading Company
Gas Pressure Regulators

Pietro Fiorentini ASX 176/FO High-Medium Pressure Gas Regulator

Axial Flow, True Fail Open

Проверенный продукт
Бренд:
Pietro Fiorentini
Код товара:
100096

ASX 176/FO is the Fail Open version of Pietro Fiorentini's axial-flow ASX 176 family: a balanced, pilot-operated plug-and-seat regulator for high-pressure transmission and medium-pressure distribution. DN 25 to DN 150, inlet 3 to 100 barg, outlet 1 to 74 barg, Cg up to 19000.

  • Accuracy class (AC)up to 2.5
  • Design standard and approvalDesigned to EN 334; certified to…
  • Downstream (outlet) pressure range Wd0.1 to 7.4 MPa | 1 to 74 barg
Скачать технический паспорт

Описание

Галерея продукта

Ключевые особенности

Pietro FiorentiniPF

Этот раздел доступен только на английском языке

  • True Fail Open plug-and-seat design per EN 334, in a balanced…
  • Inlet pressure 3 to 100 barg; outlet pressure 1 to 74 barg; minimum…
  • High capacity (Cg 630 to 19000) and high reliability with elemental…
  • Built-in pilot filter; LDB/176 silencer, PM/176 monitor and SSX/176…
  • DN 25 to DN 150, ASME B16.5 Class 300 or 600, RF or RTJ; bubble-tight…
  • Hydrogen Ready for NG-H2 blending (20% compatible; higher on…

Типовые применения

Посмотреть все применения
  • Gas transmission stations where supply continuity matters…

    Gas transmission stations where supply continuity matters…

  • Power-generation fuel-gas supply and gas-reverse-flow…

    Power-generation fuel-gas supply and gas-reverse-flow…

  • LNG marine transportation and gas liquefaction

    LNG marine transportation and gas liquefaction

  • Heavy industry with high gas demand

    Heavy industry with high gas demand

Описание товара

Этот раздел доступен только на английском языке

ASX 176/FO is the Fail Open version of Pietro Fiorentini's axial-flow ASX 176 family: a balanced, pilot-operated plug-and-seat regulator for high-pressure transmission and medium-pressure distribution. DN 25 to DN 150, inlet 3 to 100 barg, outlet 1 to 74 barg, Cg up to 19000.

The ASX 176/FO takes the axial body of the ASX 176 and turns it into a regulator that, by the manufacturer's description, is a true Fail Open plug-and-seat design. Under EN 334 a Fail Open regulator moves toward open if the control loop fails, which is the required behaviour where the downstream supply must not be interrupted by a regulator fault, for example when the regulator sits in series with a monitor or slam-shut that provides the overpressure protection.

Operating data that differ from the ASX 176

The FO version has a different working window: inlet pressure starts at 3 barg (the Fail Close ASX 176 starts at 0.8 barg), outlet pressure ranges from 1 to 74 barg, and the minimum operating differential pressure is 2 barg. Accuracy class is up to 2.5 and lock-up class up to 10, against 1 and 5 for the ASX 176. The three main pilots are 204/A/FO (1 to 33 barg), 205/A/FO (20 to 60 barg) and 207/A/FO (41 to 74 barg). As in the rest of the family, set-point adjustment is made by a pilot that controls the pressure on the motorization diaphragm chamber, the regulator is balanced, and the axial body keeps it reliable with elemental sulphur in the gas.

Accessories

  • LDB/176 silencer, PM/176 monitor and SSX/176 slam-shut valve.
  • Cg limiter, limit switches and position transmitter on the main regulator.
  • Pilot circuit: R14/A/S pre-regulator for high differential pressure, heating cable, PPH200 heater, CF14 or CF14/D supplementary filter and ATF 15 antifreeze.
  • Pilot versions with remote setting: /D electric, /CS pneumatic, /FIO smart unit.

The same sizing coefficients as the ASX 176 apply (Cg 630, 2300, 5000, 8800 and 19000 for DN 25 to DN 150, K1 = 145), and the standard weights are identical: 55, 72, 123, 214 and 333 kg in Class 300.

Supply through Barmaan

ASX 176/FO is supplied by Barmaan to order: send us the gas, the inlet pressure range, the required outlet set point, the maximum flow and the line size and flange class, and we quote the matching configuration, pilot range and accessories. Price, availability and lead time are confirmed in the quotation; this page does not publish a price. Barmaan is not presented here as a manufacturer; all technical data on this page is taken from the manufacturer's published flyer and technical brochure, which are attached below. Conformity documents for a specific project can be requested through the quotation.

Технические характеристики

ПараметрЗначение
General
ManufacturerPietro Fiorentini S.p.A. — Arcugnano (Vicenza), Italy
TypePilot-operated, balanced gas pressure regulator (high-medium pressure)
Fail action (EN 334)Fail Open (true plug-and-seat)
Suitable mediaPreviously filtered, non-corrosive gases (natural gas; biomethane; NG-H2 blends)
Pressure and performance
Design pressure (PS)up to 10.2 MPa | 102 barg
Inlet pressure (MAOP)0.3 to 10 MPa | 3 to 100 barg
Downstream (outlet) pressure range Wd0.1 to 7.4 MPa | 1 to 74 barg
Minimum operating differential pressure0.2 MPa | 2 barg
Accuracy class (AC)up to 2.5
Lock-up pressure class (SG)up to 10
Ambient temperature (TS)-20 °C to +60 °C
Inlet gas temperature-20 °C to +60 °C
Flow coefficient Cg by size (DN)DN 25: 630; DN 50: 2300; DN 80: 5000; DN 100: 8800; DN 150: 19000
Form factor K1145
Main pilot models and setting ranges204/A/FO: 1 to 33 barg; 205/A/FO: 20 to 60 barg; 207/A/FO: 41 to 74 barg
Pilot setting options/A manual; /D electric remote; /CS pneumatic remote; /FIO smart unit (remote setting, monitoring, flow limitation)
Construction and sizes
Nominal sizesDN 25 | 1 in; DN 50 | 2 in; DN 80 | 3 in; DN 100 | 4 in; DN 150 | 6 in
End connectionsASME B16.5 Class 300 and 600, RF or RTJ
BodySteel ASTM A350 LF2; plug ASTM A350 LF2 nickel-coated on the sealing surface
SeatPolymer / nitrile rubber vulcanized on a metal support
DiaphragmRubberized canvas (hot-pressed); sealing ring: nitrile rubber
Available accessoriesLDB/176 silencer; PM/176 monitor; SSX/176 slam-shut
Weight (standard version, by size)ANSI 300: 55 / 72 / 123 / 214 / 333 kg; ANSI 600: 55 / 74 / 126 / 225 / 365 kg (DN 25 / 50 / 80 / 100 / 150)
Face-to-face length (by size)ANSI 300: 197 / 267 / 317 / 368 / 473 mm
Standards and compliance
Design standard and approvalDesigned to EN 334; certified to Directive 2014/68/EU (PED), CE
Leakage classBubble-tight, better than Class VIII to ANSI/FCI 70-3
Hydrogen / biomethaneHydrogen Ready for NG-H2 blending; biomethane compatible; 20% hydrogen blending compatible, higher blending available on request
Просмотреть полные характеристики (PDF)

Модели для заказа

Модели-сёстры из этого семейства — информационные, не из склада.

Этот раздел доступен только на английском языке

Код моделиОписаниеДиапазон измерений
204/A/FOMain pilot 204/A/FOManual-setting main pilot for the Fail Open version; /D, /CS and /FIO remote-setting versions are listed by the manufacturer.0.1 - 3.3 MPa (1 - 33 barg)
205/A/FOMain pilot 205/A/FOManual-setting main pilot for the Fail Open version; /D, /CS and /FIO remote-setting versions are listed by the manufacturer.2 - 6 MPa (20 - 60 barg)
207/A/FOMain pilot 207/A/FOManual-setting main pilot for the Fail Open version; /D, /CS and /FIO remote-setting versions are listed by the manufacturer.4.1 - 7.4 MPa (41 - 74 barg)

Все перечисленные модели могут поставляться с требуемой сертификацией, протоколом выходного сигнала и присоединением к процессу — свяжитесь с нами или запросите предложение для точного подбора кода модели.

Загрузки и документация

Области применения и отрасли

Этот раздел доступен только на английском языке

  • Gas transmission stations where supply continuity matters…

    Gas transmission stations where supply continuity matters…

  • Power-generation fuel-gas supply and gas-reverse-flow…

    Power-generation fuel-gas supply and gas-reverse-flow…

  • Compression, booster, storage and regasification facilities

  • LNG marine transportation and gas liquefaction

    LNG marine transportation and gas liquefaction

  • Heavy industry with high gas demand

    Heavy industry with high gas demand

Отзывы

Отзывов пока нет

Будьте первым, кто оставит отзыв об этом продукте.

Часто задаваемые вопросы

Этот раздел доступен только на английском языке

When should I choose the /FO version instead of the standard ASX 176?

Choose by the failure direction your station requires. The standard ASX 176 is Fail Close; the ASX 176/FO is Fail Open, and it needs at least 3 barg inlet pressure and a 2 barg differential. Overpressure protection must then be provided by a monitor or slam-shut. Confirm with your station designer.

What are the main pilot models and ranges?

204/A/FO: 0.1 to 3.3 MPa (1 to 33 barg); 205/A/FO: 2 to 6 MPa (20 to 60 barg); 207/A/FO: 4.1 to 7.4 MPa (41 to 74 barg). All are manual-setting; remote-setting versions /D, /CS and /FIO exist.

Which pipe sizes and flange classes are available?

DN 25 (1 in), DN 50 (2 in), DN 80 (3 in), DN 100 (4 in) and DN 150 (6 in), with ASME B16.5 Class 300 or 600 flanges, RF or RTJ. Face-to-face lengths in Class 300 are 197, 267, 317, 368 and 473 mm; other connections on request to the manufacturer.

Does Barmaan publish a price and conformity documents?

No price is published; it depends on the configuration and is given by quotation. The manufacturer states the product is certified to Directive 2014/68/EU (PED) and designed to EN 334; project-specific conformity documents can be requested with the inquiry. Attached: flyer FY0004ENG rev. B, technical brochure rev. A (24 pages) and the English User, Maintenance and Warning Manual rev. D.

Похожие товары

Pietro Fiorentini Aperflux 851 — официальное фото производителя

Pietro FiorentiniAperflux 851

Gas Pressure Regulators

Цена по запросу

Pietro Fiorentini ASX 176 — официальное фото производителя

Pietro FiorentiniASX 176

Gas Pressure Regulators

Цена по запросу

Pietro Fiorentini Dixi AP — официальное фото производителя

Pietro FiorentiniDixi AP High-Medium Pressure Gas Regulator DN25

Gas Pressure Regulators

Цена по запросу