Endress+HauserProline Promag W 400
Расходомеры
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…
1 / 3ADMAG AXG — Yokogawa's ADMAG TI (Total Insight) magnetic flowmeter with dual-frequency excitation, PFA or ceramic lining, line sizes 2.5 to 500 mm, ±0.3 % of rate standard accuracy (±0.15 % high grade) and HART, Modbus, FOUNDATION Fieldbus, PROFIBUS PA or EtherNet/IP. Catalog model; supply on inquiry.
Цена
Нет в наличии — запросите предложение на поставкуОтправьте запрос, чтобы узнать цену.





Этот раздел доступен только на английском языке

Water, wastewater and sludge flow measurement

Chemical and petrochemical conductive liquids, including…

Food, beverage and pharmaceutical lines with hygienic…

Hazardous areas with explosion-protected versions and…
Этот раздел доступен только на английском языке
ADMAG AXG — Yokogawa's ADMAG TI (Total Insight) magnetic flowmeter with dual-frequency excitation, PFA or ceramic lining, line sizes 2.5 to 500 mm, ±0.3 % of rate standard accuracy (±0.15 % high grade) and HART, Modbus, FOUNDATION Fieldbus, PROFIBUS PA or EtherNet/IP. Catalog model; supply on inquiry.
The Yokogawa ADMAG AXG is the flagship of the ADMAG TI (Total Insight) series of magnetic flowmeters. It measures the flow velocity of any electrically conductive liquid from the electromotive force induced as the liquid moves through a magnetic field, and calculates instantaneous and totalized flow from it. Yokogawa's own dual-frequency excitation method keeps the reading stable even in high flow noise and in highly concentrated slurries.
The sensor is available in sizes 2.5 to 500 mm with fluorocarbon PFA lining or an alumina ceramic measuring tube, with 316L stainless steel, nickel alloy, platinum-iridium or tantalum electrodes, and with wafer, flange, union, clamp and hygienic process connections. It is built as an integral flowmeter, or as a remote sensor paired with an AXG4A, AXG1A or AXFA11G remote transmitter. Up to four current, pulse and status inputs/outputs can be configured, and communication options cover HART, BRAIN, Modbus, FOUNDATION Fieldbus, PROFIBUS PA and EtherNet/IP. Built-in diagnostics — in-line verification, flow-noise and conductivity monitoring, electrode insulation and adhesion diagnosis, wiring checks — support preventive maintenance, and an optional IEC 61508 version is usable in safety instrumented systems up to SIL2 (simplex) and SIL3 (redundant).
This page documents the catalog model from the official Yokogawa General Specifications (GS 01E22A01-01EN, 19th edition, 31 March 2022), which is attached for download. The exact line size, lining, electrode material, transmitter and approvals are fixed by the suffix code at ordering. Barmaan supplies the model on inquiry, with no price displayed here: send the line size, process fluid and conductivity, process temperature and pressure, and the output/communication you need, and we reply with availability and a quotation.
| Параметр | Значение |
|---|---|
| General | |
| Manufacturer / series | Yokogawa Electric Corporation (Japan) — ADMAG TI (Total Insight) series, AXG |
| Measuring principle | Electromagnetic (Faraday) with dual-frequency excitation |
| Construction | Integral flowmeter, or remote sensor with remote transmitter (AXG4A, AXG1A, AXFA11G) |
| Process conditions & connection | |
| Line size | 2.5 to 500 mm (0.1 to 20 in.); 500 mm with AXG1A / AXFA11G transmitter |
| Process connections | Wafer (ASME 150/300, EN PN10–40, JIS), flange (ASME 150/300/600, EN PN10–40, AS, JIS, JPI), union joint, clamp (Tri-Clamp, DIN 32676, ISO 2852), union (DIN 11851, ISO 2853, SMS 1145), welded joint |
| Performance & accuracy | |
| Accuracy, standard (code B) | ±0.3 % of rate at 0.3 to 10 m/s (2.5–15 mm; ±1.0 mm/s below 0.3 m/s) and 0.15 to 10 m/s (25–400 mm; ±0.5 mm/s below 0.15 m/s) |
| Accuracy, high grade (code C) | 25 to 200 mm: ±0.15 % of rate at 1 to 10 m/s; ±0.18 % of rate ±0.2 mm/s at 0.15 to 1 m/s |
| Minimum fluid conductivity | 2.5–10 mm: 5 µS/cm; 15–125 mm: 1 µS/cm; 150–400 mm: 3 µS/cm; 500 mm: 20 µS/cm |
| Construction & materials | |
| Lining | Fluorocarbon PFA; alumina ceramics (99.8 %) measuring tube |
| Electrodes | Stainless steel 316L, nickel alloy, platinum-iridium, tantalum (PFA: 2.5–200 mm; ceramics: 15–200 mm) |
| Degree of protection | IP66/IP67, Type 4X (CSA); IP68 for submersible remote sensor (1 month, 50 m fresh water) |
| Power & output | |
| Power supply | Code 1: 100–240 V AC 50/60 Hz (80–264 V) or 100–120 V DC; code 2: 24 V AC/DC (20.4–28.8 V) |
| Outputs / communication | Up to four I/O (4–20 mA, pulse, status); HART, BRAIN, Modbus, FOUNDATION Fieldbus, PROFIBUS PA, EtherNet/IP |
| Maximum cable length (remote) | 100 m with AXG4A; 200 m with AXG1A / AXFA11G; 5 m for marine approval type |
| Approvals & safety | |
| Functional safety | Optional IEC 61508: SIL2 simplex, SIL3 redundant |
| Use types | General-purpose, submersible, explosion protection, hygienic, hygienic + explosion protection, pulp & paper (blow line, circulation/extraction line) |
Модели-сёстры из этого семейства — информационные, не из склада.
Этот раздел доступен только на английском языке
| Код модели | Описание | Диапазон измерений |
|---|---|---|
| AXG-INTEGRAL | AXG integral flowmeterSensor and transmitter in one housing; available in general-purpose, explosion-protected and hygienic versions. | — |
| AXG-REMOTE | AXG remote sensor + remote transmitterSensor 2.5–500 mm with AXG4A (up to 100 m cable), AXG1A or AXFA11G (up to 200 m); submersible IP68 option. | 2.5–500 mm |
Все перечисленные модели могут поставляться с требуемой сертификацией, протоколом выходного сигнала и присоединением к процессу — свяжитесь с нами или запросите предложение для точного подбора кода модели.
Этот раздел доступен только на английском языке

Water, wastewater and sludge flow measurement

Chemical and petrochemical conductive liquids, including…
Pulp and paper (blow line, circulation/extraction line) and…

Food, beverage and pharmaceutical lines with hygienic…

Hazardous areas with explosion-protected versions and…
Отзывов пока нет
Будьте первым, кто оставит отзыв об этом продукте.
Этот раздел доступен только на английском языке
This page documents the catalog model from the official Yokogawa specifications. Availability, condition (new or used) and lead time are confirmed per inquiry; no stock or price is claimed here.
The line size, process fluid and its conductivity, process temperature and pressure, lining and electrode material you require, integral or remote type, power supply, and the output/communication (HART, Modbus, FOUNDATION Fieldbus, PROFIBUS PA, EtherNet/IP). The full suffix code is the most precise way to specify it.
No. A magnetic flowmeter needs a conductive liquid; the AXG specifies a minimum conductivity of 1 to 20 µS/cm depending on line size (for example 1 µS/cm for 15–125 mm). For hydrocarbons and gases consider a vortex or Coriolis meter.
Yokogawa General Specifications GS 01E22A01-01EN (ADMAG TI series AXG, 19th edition, 31 March 2022), attached as a PDF on this page. Check the current edition on Yokogawa's website before ordering.

Расходомеры
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

Расходомеры
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Расходомеры
HART, Modbus RS485, IO-Link; 4–20 mA; pulse/frequency/switch…

Расходомеры
4–20 mA HART + Pulse/Frequency (I-OUT, f-OUT)
Отправка в течение 1 дня
от 4 000 $

Расходомеры
M-Bus, wireless M-Bus, Modbus, BACnet, LoRa … (2 module slots)

Расходомеры
LTE Cat M1, Cat NB1, Cat NB2, GPRS, EGPRS; Modbus RS485; 3x…

Расходомеры
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Расходомеры

Расходомеры
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…
Калибровка, испытания и поставка для этого оборудования