Endress+HauserProline Promag W 400
流量计
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…
1 / 3ADMAG AXG — Yokogawa's ADMAG TI (Total Insight) magnetic flowmeter with dual-frequency excitation, PFA or ceramic lining, line sizes 2.5 to 500 mm, ±0.3 % of rate standard accuracy (±0.15 % high grade) and HART, Modbus, FOUNDATION Fieldbus, PROFIBUS PA or EtherNet/IP. Catalog model; supply on inquiry.





本节目前仅提供英文版本

Water, wastewater and sludge flow measurement

Chemical and petrochemical conductive liquids, including…

Food, beverage and pharmaceutical lines with hygienic…

Hazardous areas with explosion-protected versions and…
本节目前仅提供英文版本
ADMAG AXG — Yokogawa's ADMAG TI (Total Insight) magnetic flowmeter with dual-frequency excitation, PFA or ceramic lining, line sizes 2.5 to 500 mm, ±0.3 % of rate standard accuracy (±0.15 % high grade) and HART, Modbus, FOUNDATION Fieldbus, PROFIBUS PA or EtherNet/IP. Catalog model; supply on inquiry.
The Yokogawa ADMAG AXG is the flagship of the ADMAG TI (Total Insight) series of magnetic flowmeters. It measures the flow velocity of any electrically conductive liquid from the electromotive force induced as the liquid moves through a magnetic field, and calculates instantaneous and totalized flow from it. Yokogawa's own dual-frequency excitation method keeps the reading stable even in high flow noise and in highly concentrated slurries.
The sensor is available in sizes 2.5 to 500 mm with fluorocarbon PFA lining or an alumina ceramic measuring tube, with 316L stainless steel, nickel alloy, platinum-iridium or tantalum electrodes, and with wafer, flange, union, clamp and hygienic process connections. It is built as an integral flowmeter, or as a remote sensor paired with an AXG4A, AXG1A or AXFA11G remote transmitter. Up to four current, pulse and status inputs/outputs can be configured, and communication options cover HART, BRAIN, Modbus, FOUNDATION Fieldbus, PROFIBUS PA and EtherNet/IP. Built-in diagnostics — in-line verification, flow-noise and conductivity monitoring, electrode insulation and adhesion diagnosis, wiring checks — support preventive maintenance, and an optional IEC 61508 version is usable in safety instrumented systems up to SIL2 (simplex) and SIL3 (redundant).
This page documents the catalog model from the official Yokogawa General Specifications (GS 01E22A01-01EN, 19th edition, 31 March 2022), which is attached for download. The exact line size, lining, electrode material, transmitter and approvals are fixed by the suffix code at ordering. Barmaan supplies the model on inquiry, with no price displayed here: send the line size, process fluid and conductivity, process temperature and pressure, and the output/communication you need, and we reply with availability and a quotation.
| 参数项 | 参数值 |
|---|---|
| General | |
| Manufacturer / series | Yokogawa Electric Corporation (Japan) — ADMAG TI (Total Insight) series, AXG |
| Measuring principle | Electromagnetic (Faraday) with dual-frequency excitation |
| Construction | Integral flowmeter, or remote sensor with remote transmitter (AXG4A, AXG1A, AXFA11G) |
| Process conditions & connection | |
| Line size | 2.5 to 500 mm (0.1 to 20 in.); 500 mm with AXG1A / AXFA11G transmitter |
| Process connections | Wafer (ASME 150/300, EN PN10–40, JIS), flange (ASME 150/300/600, EN PN10–40, AS, JIS, JPI), union joint, clamp (Tri-Clamp, DIN 32676, ISO 2852), union (DIN 11851, ISO 2853, SMS 1145), welded joint |
| Performance & accuracy | |
| Accuracy, standard (code B) | ±0.3 % of rate at 0.3 to 10 m/s (2.5–15 mm; ±1.0 mm/s below 0.3 m/s) and 0.15 to 10 m/s (25–400 mm; ±0.5 mm/s below 0.15 m/s) |
| Accuracy, high grade (code C) | 25 to 200 mm: ±0.15 % of rate at 1 to 10 m/s; ±0.18 % of rate ±0.2 mm/s at 0.15 to 1 m/s |
| Minimum fluid conductivity | 2.5–10 mm: 5 µS/cm; 15–125 mm: 1 µS/cm; 150–400 mm: 3 µS/cm; 500 mm: 20 µS/cm |
| Construction & materials | |
| Lining | Fluorocarbon PFA; alumina ceramics (99.8 %) measuring tube |
| Electrodes | Stainless steel 316L, nickel alloy, platinum-iridium, tantalum (PFA: 2.5–200 mm; ceramics: 15–200 mm) |
| Degree of protection | IP66/IP67, Type 4X (CSA); IP68 for submersible remote sensor (1 month, 50 m fresh water) |
| Power & output | |
| Power supply | Code 1: 100–240 V AC 50/60 Hz (80–264 V) or 100–120 V DC; code 2: 24 V AC/DC (20.4–28.8 V) |
| Outputs / communication | Up to four I/O (4–20 mA, pulse, status); HART, BRAIN, Modbus, FOUNDATION Fieldbus, PROFIBUS PA, EtherNet/IP |
| Maximum cable length (remote) | 100 m with AXG4A; 200 m with AXG1A / AXFA11G; 5 m for marine approval type |
| Approvals & safety | |
| Functional safety | Optional IEC 61508: SIL2 simplex, SIL3 redundant |
| Use types | General-purpose, submersible, explosion protection, hygienic, hygienic + explosion protection, pulp & paper (blow line, circulation/extraction line) |
同系列的其他型号 — 仅供参考,非库存产品。
本节目前仅提供英文版本
| 型号代码 | 说明 | 测量范围 |
|---|---|---|
| AXG-INTEGRAL | AXG integral flowmeterSensor and transmitter in one housing; available in general-purpose, explosion-protected and hygienic versions. | — |
| AXG-REMOTE | AXG remote sensor + remote transmitterSensor 2.5–500 mm with AXG4A (up to 100 m cable), AXG1A or AXFA11G (up to 200 m); submersible IP68 option. | 2.5–500 mm |
所列全部型号均可按您所需的认证、输出协议及过程连接方式供货 — 如需确定具体型号代码,请联系我们或提交询价。
本节目前仅提供英文版本

Water, wastewater and sludge flow measurement

Chemical and petrochemical conductive liquids, including…
Pulp and paper (blow line, circulation/extraction line) and…

Food, beverage and pharmaceutical lines with hygienic…

Hazardous areas with explosion-protected versions and…
暂无评论
成为第一个评论此产品的人。
本节目前仅提供英文版本
This page documents the catalog model from the official Yokogawa specifications. Availability, condition (new or used) and lead time are confirmed per inquiry; no stock or price is claimed here.
The line size, process fluid and its conductivity, process temperature and pressure, lining and electrode material you require, integral or remote type, power supply, and the output/communication (HART, Modbus, FOUNDATION Fieldbus, PROFIBUS PA, EtherNet/IP). The full suffix code is the most precise way to specify it.
No. A magnetic flowmeter needs a conductive liquid; the AXG specifies a minimum conductivity of 1 to 20 µS/cm depending on line size (for example 1 µS/cm for 15–125 mm). For hydrocarbons and gases consider a vortex or Coriolis meter.
Yokogawa General Specifications GS 01E22A01-01EN (ADMAG TI series AXG, 19th edition, 31 March 2022), attached as a PDF on this page. Check the current edition on Yokogawa's website before ordering.

流量计
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

流量计
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

流量计
HART, Modbus RS485, IO-Link; 4–20 mA; pulse/frequency/switch…

流量计
4–20 mA HART + Pulse/Frequency (I-OUT, f-OUT)
1天内发货
起 US$4,000

流量计
M-Bus, wireless M-Bus, Modbus, BACnet, LoRa … (2 module slots)

流量计
LTE Cat M1, Cat NB1, Cat NB2, GPRS, EGPRS; Modbus RS485; 3x…

流量计
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

流量计

流量计
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…
面向此类设备的校准、检测与供应服务