Endress+HauserProline Promag W 400
流量计
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

The Prosonic Flow W 400 is the ultrasonic clamp-on flowmeter of choice for safe, cost-effective and maintenance-free measurement of conductive and non-conductive liquids, measuring non-invasively and bidirectionally.


本节目前仅提供英文版本

Water and wastewater, process water and hydropower plants.
Large pipes up to DN 4000 where a clamp-on system is far…
Retrofit and temporary checks on existing lines without…
Plastic and GRP pipes with dedicated transducers.
本节目前仅提供英文版本
The Prosonic Flow W 400 is the ultrasonic clamp-on flowmeter of choice for safe, cost-effective and maintenance-free measurement of conductive and non-conductive liquids, measuring non-invasively and bidirectionally.
Endress+Hauser Proline Prosonic Flow W 400 Ultrasonic Clamp-on Flowmeter: The Prosonic Flow W 400 is the ultrasonic clamp-on flowmeter of choice for safe, cost-effective and maintenance-free measurement of conductive and non-conductive liquids, measuring non-invasively and bidirectionally.
An ultrasonic clamp-on (time-of-flight) flowmeter measures from outside the pipe: transducers fixed to the pipe wall send ultrasonic signals with and against the flow, and the transit-time difference gives the flow velocity. Nothing enters the pipe, so it can be mounted without cutting the pipe or interrupting the process. According to the manufacturer, the principle is non-invasive and independent of pressure, density and conductivity.
A wide nominal diameter range of DN 15 to 4000 (½ to 160"), medium temperatures up to +130 °C, a polycarbonate or aluminium transmitter housing and a remote version for wall mounting. Key figures from the official data: nominal diameter DN 15–4000; maximum measured error ±2 % o.r.; measuring range 0–15 m/s; medium temperature –40…+130 °C.
Barmaan supplies this model by order code on inquiry; there is no list price on the page. Send the nominal diameter, medium, process connection and the required outputs, and we will confirm the configuration against the official Technical Information.
| 参数项 | 参数值 |
|---|---|
| General | |
| Measuring principle | Ultrasonic time-of-flight, clamp-on |
| Nominal diameter range | DN 15 to 4000 (½ to 160") |
| Approvals and certificates | Heartbeat Technology (diagnostics, verification, monitoring); see Technical Information TI01568D for certificates |
| Official document | Technical Information TI01568D |
| Performance & accuracy | |
| Maximum measured error | Volume flow: ±3 % o.r. (DN 15); ±2 % o.r. (DN 25 to 200); ±2 % o.r. (above DN 200) |
| Measuring range | 0 to 15 m/s (0 to 50 ft/s) |
| Process conditions | |
| Medium temperature range | –40 to +130 °C (–40 to +266 °F) |
| Wetted materials | Sensor holder and sensor housing: stainless steel 1.4404 (316L); transmitter: polycarbonate or aluminium |
| Electrical & communication | |
| Display / operation | Display with touch control and backlighting; web server for full remote access; integrated data logger |
本节目前仅提供英文版本

Water and wastewater, process water and hydropower plants.
Large pipes up to DN 4000 where a clamp-on system is far…
Retrofit and temporary checks on existing lines without…
Plastic and GRP pipes with dedicated transducers.
暂无评论
成为第一个评论此产品的人。
本节目前仅提供英文版本
No. The transducers are mounted on the outside of the pipe, so installation does not interrupt the process.
With FlowDC the specified accuracy is maintained at an inlet run of only 2 x DN, even in disturbed flow profiles.
Yes. The manufacturer describes it as suitable for conductive and non-conductive liquids; the principle is independent of conductivity.
The manufacturer specifies a maximum measured error for volume flow of ±3 % o.r. for DN 15, ±2 % o.r. for DN 25 to 200 and ±2 % o.r. above DN 200.
The official Endress+Hauser Technical Information TI01568D is attached in the downloads section of this page, so you have the full specification and ordering information.
Pricing depends on nominal diameter, process connection, materials, approvals and the transmitter configuration (order code). Send us your requirements and we quote it on request.

流量计
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

流量计
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

流量计
HART, Modbus RS485, IO-Link; 4–20 mA; pulse/frequency/switch…

流量计
4–20 mA HART + Pulse/Frequency (I-OUT, f-OUT)
1天内发货
起 US$4,000

流量计
M-Bus, wireless M-Bus, Modbus, BACnet, LoRa … (2 module slots)

流量计
LTE Cat M1, Cat NB1, Cat NB2, GPRS, EGPRS; Modbus RS485; 3x…

流量计
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

流量计

流量计
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…
面向此类设备的校准、检测与供应服务