KROHNE OPTIMASS 6400 — twin V-tube Coriolis mass flowmeter (6400C compact, 6400F remote) with MFC 400 converter: mass, density and temperature, ±0.1 % mass accuracy (±0.05 % option), -200 to +400 °C, sizes 08 to 200, up to 200 barg. Catalog model; supply on inquiry.

  • Mass flow accuracy (liquid)±0.1 % of measured flow rate…
  • Mass flow accuracy (gas)±0.35 % of actual measured flow rate ±…
  • Measuring principleCoriolis mass flow, twin V-shaped…
下载数据表

商品介绍

产品图库

主要特点

KROHNEK

本节目前仅提供英文版本

  • Twin V-tube design with an optimised flow divider for minimum…
  • Temperature range from -200 to +400 °C, with optional insulation /…
  • Entrained Gas Management (EGM) keeps the meter in operation over wide…
  • Modular electronics: electronics and sensor are easy to replace…
  • Direct measurement of mass flow, density and temperature in one…
  • Calibration rig accredited to the requirements of BS EN ISO / IEC…
  • Custody-transfer-grade liquid and gas measurement, tanker…

    Custody-transfer-grade liquid and gas measurement, tanker…

  • Liquefied natural gas (LNG), cryogenic and supercritical…

    Liquefied natural gas (LNG), cryogenic and supercritical…

  • Chemical, oil and gas, food and beverage, and…

    Chemical, oil and gas, food and beverage, and…

  • Water and wastewater treatment dosing and mass-based…

    Water and wastewater treatment dosing and mass-based…

产品概览

本节目前仅提供英文版本

KROHNE OPTIMASS 6400 — twin V-tube Coriolis mass flowmeter (6400C compact, 6400F remote) with MFC 400 converter: mass, density and temperature, ±0.1 % mass accuracy (±0.05 % option), -200 to +400 °C, sizes 08 to 200, up to 200 barg. Catalog model; supply on inquiry.

The KROHNE OPTIMASS 6400 is a high-performance Coriolis mass flowmeter for the process industries. A fully welded, maintenance-free sensor with two V-shaped measuring tubes is driven to oscillate; the Coriolis effect shifts the phase of the signals picked up on either side of the drive coil in proportion to mass flow, while the oscillation frequency gives density and a Pt500 sensor gives temperature. From these the meter outputs mass flow, density and temperature and calculates volume flow, referred density, concentration and velocity.

The official KROHNE technical datasheet (document TD OPTIMASS 6000 R06 en, 01/2025, which covers the OPTIMASS 6400C compact and 6400F remote versions with the MFC 400 converter) lists a 316L stainless steel sensor in sizes 08 to 200 with 100 barg at 20 °C, Hastelloy sizes 08 to 80 and duplex stainless steel sizes 100 to 200 with 200 barg, a process temperature range of -200 to +400 °C, a maximum permissible mass flow error of ±0.1 % of the measured flow rate for liquids (±0.05 % optional) and ±0.35 % for gases, density accuracy of ±1 kg/m³ over 100 to 3000 kg/m³, nominal flow rates up to 550000 kg/h, and flanges up to 1500 lb / PN160 with optional hygienic connections. The advanced Entrained Gas Management (EGM) keeps the meter operating over wide gas fractions, and the twin V-tube design with an optimised flow divider gives low pressure loss and self-draining when mounted vertically.

This page documents the catalog model; the sensor size, material, converter and approvals are fixed by the order code. Barmaan supplies the model on inquiry and shows no price here: send the fluid, mass flow range, line size, temperature and pressure and the output/communication you need, and we reply with availability and a quotation.

技术规格

参数项参数值
General
Manufacturer / seriesKROHNE (Germany) — OPTIMASS 6400 (datasheet shared with OPTIMASS 6000 series)
Measuring principleCoriolis mass flow, twin V-shaped measuring tubes; Pt500 temperature sensor
Versions / converter6400C compact, 6400F remote field; MFC 400 signal converter
Measured valuesMass flow, density, temperature; calculated: volume flow, referred density, concentration, velocity
Performance & accuracy
Mass flow accuracy (liquid)±0.1 % of measured flow rate (standard); ±0.05 % (optional); repeatability better than 0.05 % (0.025 % optional)
Mass flow accuracy (gas)±0.35 % of actual measured flow rate ± zero stability
DensityRange 100 to 3000 kg/m³; base accuracy ±1 kg/m³; repeatability / on-site calibration ±0.3 kg/m³
Temperature measurement±0.5 °C ± 0.5 % of reading
Process conditions & connection
Sensor sizes / materials316L stainless steel 08–200 (100 barg); Hastelloy 08–80 (200 barg); duplex stainless steel 100–200 (200 barg)
Process temperature-200 to +400 °C depending on version (standard -70 to +230 °C; high temperature -50 to +400 °C; cryogenic -200 to +40 °C)
Nominal flow rateFrom 600 kg/h (size 08) to 550000 kg/h (size 200) at 1 barg pressure drop; maximum 150 % of nominal
FlangesStandard flanges up to 1500 lb / PN160; hygienic connections, optional sealing faces, NAMUR NE132 lengths
Construction & materials
Ambient temperature (compact)-40 to +65 °C (aluminium converter); -40 to +60 °C (stainless steel converter); SIL-capable converter -40 to +55 °C
Degree of protectionIP 66 / 67, NEMA 4X
DesignFully welded, maintenance-free sensor; self-draining when mounted vertically; optional heating/insulation jacket and purge port
查看完整规格(PDF)

可订购型号

同系列的其他型号 — 仅供参考,非库存产品。

本节目前仅提供英文版本

型号代码说明测量范围
6400COPTIMASS 6400 C — compactConverter MFC 400 mounted on the sensor.08–200
6400FOPTIMASS 6400 F — remote fieldSensor with a remote terminal box and field converter MFC 400; includes the +400 °C high-temperature range.08–200

所列全部型号均可按您所需的认证、输出协议及过程连接方式供货 — 如需确定具体型号代码,请联系我们或提交询价。

资料下载与文档

应用领域与行业

本节目前仅提供英文版本

  • Custody-transfer-grade liquid and gas measurement, tanker…

    Custody-transfer-grade liquid and gas measurement, tanker…

  • Liquefied natural gas (LNG), cryogenic and supercritical…

    Liquefied natural gas (LNG), cryogenic and supercritical…

  • Chemical, oil and gas, food and beverage, and…

    Chemical, oil and gas, food and beverage, and…

  • Water and wastewater treatment dosing and mass-based…

    Water and wastewater treatment dosing and mass-based…

  • Crystallising, solidifying and high-temperature products…

评论

暂无评论

成为第一个评论此产品的人。

常见问题解答

本节目前仅提供英文版本

Is it in stock, and what is the price?

This is a catalog model documented from the manufacturer's datasheet. Availability, condition and lead time are confirmed per inquiry, and no price is published on this page.

What is the difference between 6400C and 6400F?

Both use the same OPTIMASS sensor with the MFC 400 converter. 6400C is the compact version with the converter on the sensor; 6400F is the remote field version with the converter mounted separately.

Which document is the source, and is it the OPTIMASS 6400 datasheet?

KROHNE technical datasheet TD OPTIMASS 6000 R06 en (01/2025). KROHNE publishes one datasheet for the OPTIMASS 6000 sensor family, and it explicitly lists the 6400C and 6400F versions; a KROHNE Quick Start guide (R03, 03/2022) is attached as well. The copy comes from a distributor mirror because the official download list could not be fetched; verify the current revision at krohne.com before ordering.

What do I need to send for a quotation?

The fluid, mass flow range, line size and flange standard, process temperature and pressure, sensor material, compact or remote version, and the required outputs/communication; the full order code is the most precise way.

为何选择Barmaan的检验库存

  • 发货前经过检验测试
  • 30天功能保修
  • 真伪通过铭牌与订购代码核验
  • 按订单采购——交期在询价回复中确认
  • 送达项目现场
  • 售后支持
在WhatsApp上咨询+964 751 113 9532

相关产品

缺货
Endress+Hauser Proline Promag W 400 Electromagnetic Flowmeter

Endress+HauserProline Promag W 400

流量计

HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

缺货
Endress+Hauser Proline Promag H 300 Electromagnetic Flowmeter

Endress+HauserProline Promag H 300

流量计

HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

缺货
Endress+Hauser Proline Promag D 10 Electromagnetic Flowmeter

Endress+HauserProline Promag D 10

流量计

HART, Modbus RS485, IO-Link; 4–20 mA; pulse/frequency/switch…

查看全部流量计
二手3 台
Endress+Hauser Promass 83F Coriolis Flowmeter — DN50 (2"), 3 units in stock

Endress+HauserPromass 83F DN50

流量计

4–20 mA HART + Pulse/Frequency (I-OUT, f-OUT)

1天内发货

起 US$4,000

缺货
Kamstrup MULTICAL 603 Energy Meter + ULTRAFLOW Flow Sensor (Set)

KamstrupMULTICAL 603

流量计

M-Bus, wireless M-Bus, Modbus, BACnet, LoRa … (2 module slots)

缺货
Endress+Hauser Proline Promag W 800 Electromagnetic Flowmeter

Endress+HauserProline Promag W 800

流量计

LTE Cat M1, Cat NB1, Cat NB2, GPRS, EGPRS; Modbus RS485; 3x…

缺货
Endress+Hauser Proline Promass X 300 Coriolis Flowmeter

Endress+HauserProline Promass X 300

流量计

HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

缺货
Endress+Hauser Proline Promass Q 300 Coriolis Flowmeter

Endress+HauserProline Promass Q 300

流量计

缺货
Endress+Hauser Proline Promass P 300 Coriolis Flowmeter

Endress+HauserProline Promass P 300

流量计

HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

面向此类设备的校准、检测与供应服务