Pietro FiorentiniAperflux 851
Gas Pressure Regulators
价格面议

Axial Flow, Pilot-Operated, Fail Close
ASX 176 is Pietro Fiorentini's axial-flow, balanced, pilot-operated gas pressure regulator, Fail Close per EN 334. High capacity (Cg 630 to 19000), DN 25 to DN 150, inlet up to 100 barg, outlet 0.3 to 74 barg, and designed to stay reliable where elemental sulphur is present in the gas.






本节目前仅提供英文版本

City gates and gas transmission pressure-reduction stations

Power-plant fuel gas supply and gas-reverse-flow stations

Compression and booster stations, gas storage and LNG…

Regasification and gas liquefaction facilities
本节目前仅提供英文版本
ASX 176 is Pietro Fiorentini's axial-flow, balanced, pilot-operated gas pressure regulator, Fail Close per EN 334. High capacity (Cg 630 to 19000), DN 25 to DN 150, inlet up to 100 barg, outlet 0.3 to 74 barg, and designed to stay reliable where elemental sulphur is present in the gas.
ASX 176 is an axial-flow gas pressure regulator with a pilot-operated, dynamically balanced actuator. Pietro Fiorentini builds it for previously filtered, non-corrosive gases in high-pressure transmission and medium-pressure natural gas distribution, and for heavy industrial loads. In the EN 334 classification it is Fail Close: if the pilot or control loop fails, the main valve tends to close, which is the safe direction for most downstream users.
The ASX 176 is an axial-flow regulator, and the manufacturer states it has higher capacity than top-entry regulators of the same nominal size; Cg runs from 630 at DN 25 to 19000 at DN 150 (K1 = 145). The body shape also makes it highly reliable where elemental sulphur is present in the gas stream. Set-point adjustment is made by the pilot, which controls the pressure acting on the motorization diaphragm chamber. As a balanced regulator it keeps outlet pressure independent of inlet-pressure changes, with accuracy class up to 1 and lock-up class up to 5 depending on working conditions; the minimum operating differential pressure is 0.5 barg. Seat and plug sealing is bubble-tight, better than Class VIII to ANSI/FCI 70-3.
When an in-line monitor is installed upstream, the brochure advises applying a 20 percent reduction to the active regulator's Cg during sizing. Remote set-point versions of the pilot (/D, /CS, /FIO) are available.
ASX 176 is supplied by Barmaan to order: send us the gas, the inlet pressure range, the required outlet set point, the maximum flow and the line size and flange class, and we quote the matching configuration, pilot range and accessories. Price, availability and lead time are confirmed in the quotation; this page does not publish a price. Barmaan is not presented here as a manufacturer; all technical data on this page is taken from the manufacturer's published flyer and technical brochure, which are attached below. Conformity documents for a specific project can be requested through the quotation.
| 参数项 | 参数值 |
|---|---|
| General | |
| Manufacturer | Pietro Fiorentini S.p.A. — Arcugnano (Vicenza), Italy |
| Type | Pilot-operated, balanced gas pressure regulator (high-medium pressure) |
| Fail action (EN 334) | Fail Close |
| Suitable media | Previously filtered, non-corrosive gases (natural gas; biomethane; NG-H2 blends) |
| Pressure and performance | |
| Design pressure (PS) | up to 10.2 MPa | 102 barg |
| Inlet pressure (MAOP) | 0.08 to 10 MPa | 0.8 to 100 barg |
| Downstream (outlet) pressure range Wd | 0.03 to 7.4 MPa | 0.3 to 74 barg |
| Minimum operating differential pressure | 0.05 MPa | 0.5 barg |
| Accuracy class (AC) | up to 1 (depending on working conditions) |
| Lock-up pressure class (SG) | up to 5 (depending on working conditions) |
| Ambient temperature (TS) | -20 °C to +60 °C |
| Inlet gas temperature | -20 °C to +60 °C |
| Flow coefficient Cg by size (DN) | DN 25: 630; DN 50: 2300; DN 80: 5000; DN 100: 8800; DN 150: 19000 |
| Form factor K1 | 145 |
| Main pilot models and setting ranges | 204/A: 0.3 to 43 barg; 205/A: 20 to 60 barg; 207/A: 41 to 74 barg |
| Pilot setting options | /A manual; /D electric remote; /CS pneumatic remote; /FIO smart unit (remote setting, monitoring, flow limitation) |
| Construction and sizes | |
| Nominal sizes | DN 25 | 1 in; DN 50 | 2 in; DN 80 | 3 in; DN 100 | 4 in; DN 150 | 6 in |
| End connections | ASME B16.5 Class 300 and 600, RF or RTJ |
| Body | Steel ASTM A350 LF2; plug ASTM A350 LF2 nickel-coated on the sealing surface |
| Seat | Polymer / nitrile rubber vulcanized on a metal support |
| Diaphragm | Rubberized canvas (hot-pressed); sealing ring: nitrile rubber |
| Available accessories | LDB/176 silencer; PM/176 monitor; SSX/176 slam-shut |
| Weight (standard version, by size) | ANSI 300: 55 / 72 / 123 / 214 / 333 kg; ANSI 600: 55 / 74 / 126 / 225 / 365 kg (DN 25 / 50 / 80 / 100 / 150) |
| Face-to-face length (by size) | ANSI 300: 197 / 267 / 317 / 368 / 473 mm; ANSI 600: 210 / 286 / 336 / 394 / 508 mm |
| Standards and compliance | |
| Design standard and approval | Designed to EN 334; certified to Directive 2014/68/EU (PED), CE |
| Leakage class | Bubble-tight, better than Class VIII to ANSI/FCI 70-3 |
| Hydrogen / biomethane | Hydrogen Ready for NG-H2 blending; biomethane compatible; 20% hydrogen blending compatible, higher blending available on request |
同系列的其他型号 — 仅供参考,非库存产品。
本节目前仅提供英文版本
| 型号代码 | 说明 | 测量范围 |
|---|---|---|
| 204/A | Main pilot 204/AManual-setting main pilot; /D electric, /CS pneumatic and /FIO smart remote-setting versions are listed by the manufacturer. | 0.03 - 4.3 MPa (0.3 - 43 barg) |
| 205/A | Main pilot 205/AManual-setting main pilot; /D electric, /CS pneumatic and /FIO smart remote-setting versions are listed by the manufacturer. | 2 - 6 MPa (20 - 60 barg) |
| 207/A | Main pilot 207/AManual-setting main pilot; /D electric, /CS pneumatic and /FIO smart remote-setting versions are listed by the manufacturer. | 4.1 - 7.4 MPa (41 - 74 barg) |
所列全部型号均可按您所需的认证、输出协议及过程连接方式供货 — 如需确定具体型号代码,请联系我们或提交询价。
本节目前仅提供英文版本

City gates and gas transmission pressure-reduction stations

Power-plant fuel gas supply and gas-reverse-flow stations

Compression and booster stations, gas storage and LNG…

Regasification and gas liquefaction facilities

Heavy industry with large gas demand
暂无评论
成为第一个评论此产品的人。
本节目前仅提供英文版本
They share the same axial body, sizes and Cg values. The ASX 176 is Fail Close (inlet pressure from 0.8 barg, minimum differential 0.5 barg, accuracy class up to 1, lock-up up to 5). The ASX 176/FO is a true Fail Open plug-and-seat regulator (inlet from 3 barg, minimum differential 2 barg, accuracy up to 2.5, lock-up up to 10). Choose according to the safe failure direction of your station.
The manufacturer states that the body form factor of the ASX 176 makes it very reliable for applications with high elemental sulphur presence in the gas stream. The brochure does not quantify sulphur limits, so give your gas analysis in the inquiry.
Inlet pressure 0.8 to 100 barg and outlet pressure 0.3 to 74 barg (design pressure up to 102 barg). The main pilot models are 204/A (0.3 to 43 barg), 205/A (20 to 60 barg) and 207/A (41 to 74 barg).
For Class 300 the standard regulator weighs 55, 72, 123, 214 and 333 kg for DN 25, 50, 80, 100 and 150; face-to-face lengths are 197, 267, 317, 368 and 473 mm. Class 600 weights are 55, 74, 126, 225 and 365 kg. Versions with silencer, monitor or slam-shut have their own dimension tables in the brochure.
No price is published; it is quoted per project. Attached are the manufacturer's flyer (FY0003ENG rev. B), the 24-page technical brochure (rev. A-1) and the English User, Maintenance and Warning Manual (rev. D, 02/2026).