Pietro FiorentiniASX 176
Gas Pressure Regulators
价格面议

Pilot-Operated, Fail Open
Aperflux 851 is Pietro Fiorentini's balanced, pilot-operated, top-entry gas pressure regulator for high-pressure transmission and medium-pressure distribution. Fail Open per EN 334, DN 25 to DN 250, inlet up to 85 barg, outlet 0.8 to 74 barg, with optional silencer, slam-shut and monitor built into the same body.






本节目前仅提供英文版本

City-gate stations in high-pressure gas transmission

Gas compression and booster stations

Gas storage and regasification plants

Heavy industry and large industrial gas consumers
本节目前仅提供英文版本
Aperflux 851 is Pietro Fiorentini's balanced, pilot-operated, top-entry gas pressure regulator for high-pressure transmission and medium-pressure distribution. Fail Open per EN 334, DN 25 to DN 250, inlet up to 85 barg, outlet 0.8 to 74 barg, with optional silencer, slam-shut and monitor built into the same body.
The Aperflux 851 is a pilot-operated gas pressure regulator designed and manufactured by Pietro Fiorentini for previously filtered, non-corrosive gases. The manufacturer positions it mainly for high-pressure transmission systems and for medium-pressure natural gas distribution networks, and classifies it as Fail Open under EN 334: if the control loop fails, the main valve moves toward the open position, so it is normally paired with a slam-shut or an in-line monitor for overpressure protection.
Aperflux 851 is a balanced regulator: the controlled outlet pressure is not affected by variations in inlet pressure or flow, so a single-size orifice serves all pressure and flow conditions. Set-point adjustment is made through the pilot, which loads and unloads pressure in the upper diaphragm chamber of the main valve. The manufacturer describes a dynamic balancing system that gives a high turn-down ratio with accurate outlet-pressure control, a built-in pilot filter, and operation at low differential pressure (minimum 0.5 barg, 2 barg recommended). It is a true top-entry design: internal parts can be maintained in the field without removing the body from the pipework.
Per the brochure, the built-in silencer, slam-shut or monitor each lower the Cg by about 5 percent compared with the plain version, and all can be retrofitted without removing the body from the line.
Aperflux 851 is supplied by Barmaan to order: send us the gas, the inlet pressure range, the required outlet set point, the maximum flow and the line size and flange class, and we quote the matching configuration, pilot range and accessories. Price, availability and lead time are confirmed in the quotation; this page does not publish a price. Barmaan is not presented here as a manufacturer; all technical data on this page is taken from the manufacturer's published flyer and technical brochure, which are attached below. Conformity documents for a specific project can be requested through the quotation.
| 参数项 | 参数值 |
|---|---|
| General | |
| Manufacturer | Pietro Fiorentini S.p.A. — Arcugnano (Vicenza), Italy |
| Type | Pilot-operated, balanced gas pressure regulator (high-medium pressure) |
| Fail action (EN 334) | Fail Open |
| Suitable media | Previously filtered, non-corrosive gases (natural gas; biomethane; NG-H2 blends) |
| Pressure and performance | |
| Design pressure (PS) | up to 10.2 MPa | 102 barg |
| Inlet pressure (MAOP) | 0.13 to 8.5 MPa | 1.3 to 85 barg |
| Downstream (outlet) pressure range Wd | 0.08 to 7.4 MPa | 0.8 to 74 barg |
| Minimum operating differential pressure | 0.05 MPa | 0.5 barg (recommended 0.2 MPa | 2 barg) |
| Accuracy class (AC) | up to 2.5 (depending on working conditions) |
| Lock-up pressure class (SG) | up to 10 (depending on working conditions) |
| Ambient temperature (TS) | -20 °C to +60 °C |
| Inlet gas temperature | -20 °C to +60 °C |
| Flow coefficient Cg by size (DN) | DN 25: 480; DN 50: 1550; DN 80: 3790; DN 100: 5554; DN 150: 11112; DN 200: 17316; DN 250: 24548 |
| Form factor K1 | 113.9 |
| Main pilot models and setting ranges | 302/A: 0.8 to 9.5 barg; 304/A: 7 to 43 barg; 305/A: 20 to 60 barg; 307/A: 41 to 74 barg |
| Pilot setting options | /A manual; /D electric remote; /CS pneumatic remote; /FIO smart unit (remote setting, monitoring, flow limitation) |
| Construction and sizes | |
| Nominal sizes | DN 25 | 1 in; DN 50 | 2 in; DN 80 | 3 in; DN 100 | 4 in; DN 150 | 6 in; DN 200 | 8 in; DN 250 | 10 in |
| End connections | ASME B16.5 Class 150/300/600 RF or RTJ; ISO 7005 PN 16/25/40 |
| Body | Cast steel ASTM A352 LCC (Class 300 and 600); ASTM A216 WCB (Class 150 and PN 16); cover in rolled or forged carbon steel |
| Seat | Stainless steel for DN ≤ 3 in; carbon steel with stainless-steel seal edge for 4 in and above |
| Diaphragm | Vulcanized rubber (sealing ring: nitrile rubber) |
| Available accessories | DB/851 silencer; SB/82 slam-shut; HB/97 slam-shut; PM/819 monitor; opening indicator |
| Weight (standard version, by size) | ANSI 300: 21 / 36 / 82 / 128 / 257 / 395 / 750 kg (DN 25 / 50 / 80 / 100 / 150 / 200 / 250) |
| Face-to-face length (by size) | ANSI 300: 197 / 267 / 317 / 368 / 473 / 568 / 708 mm (DN 25 to DN 250) |
| Standards and compliance | |
| Design standard and approval | Designed to EN 334; certified to Directive 2014/68/EU (PED), CE |
| Leakage class | Bubble-tight, better than Class VIII to ANSI/FCI 70-3 |
| Hydrogen / biomethane | Hydrogen Ready for NG-H2 blending; biomethane compatible; 20% hydrogen blending compatible, higher blending available on request |
同系列的其他型号 — 仅供参考,非库存产品。
本节目前仅提供英文版本
| 型号代码 | 说明 | 测量范围 |
|---|---|---|
| 302/A | Main pilot 302/AManual-setting main pilot; the manufacturer also lists /D electric, /CS pneumatic and /FIO smart remote-setting versions. | 0.08 - 0.95 MPa (0.8 - 9.5 barg) |
| 304/A | Main pilot 304/AManual-setting main pilot; the manufacturer also lists /D electric, /CS pneumatic and /FIO smart remote-setting versions. | 0.7 - 4.3 MPa (7 - 43 barg) |
| 305/A | Main pilot 305/AManual-setting main pilot; the manufacturer also lists /D electric, /CS pneumatic and /FIO smart remote-setting versions. | 2 - 6 MPa (20 - 60 barg) |
| 307/A | Main pilot 307/AManual-setting main pilot; the manufacturer also lists /D electric, /CS pneumatic and /FIO smart remote-setting versions. | 4.1 - 7.4 MPa (41 - 74 barg) |
所列全部型号均可按您所需的认证、输出协议及过程连接方式供货 — 如需确定具体型号代码,请联系我们或提交询价。
本节目前仅提供英文版本

City-gate stations in high-pressure gas transmission

Gas compression and booster stations

Gas storage and regasification plants

Heavy industry and large industrial gas consumers

Gas liquefaction facilities and medium-pressure…
暂无评论
成为第一个评论此产品的人。
本节目前仅提供英文版本
Under EN 334 the Aperflux 851 is classified as Fail Open: if the loading pressure or the pilot circuit fails, the main valve tends to move to the open position. For this reason the manufacturer offers the SB/82 or HB/97 slam-shut and the PM/819 monitor on the same body. Which protection is required is decided by your station design and the applicable code.
Design pressure up to 102 barg, inlet pressure (MAOP) from 1.3 to 85 barg, outlet pressure from 0.8 to 74 barg, in sizes DN 25 (1 in), 50, 80, 100, 150, 200 and DN 250 (10 in). The main pilot models are 302/A (0.8 to 9.5 barg), 304/A (7 to 43 barg), 305/A (20 to 60 barg) and 307/A (41 to 74 barg). Accuracy class is up to 2.5 and lock-up class up to 10, depending on working conditions.
The manufacturer states that the Aperflux 851 is Hydrogen Ready for NG-H2 blending, biomethane compatible and compatible with 20% hydrogen blending, with higher blending available on request. If your project involves a higher hydrogen content, state the percentage in your inquiry so the configuration can be confirmed with the manufacturer.
No. The price depends on size, flange class, pilot range, accessories and quantity, so it is given in a quotation. Send the line size, inlet and outlet pressures, maximum flow and gas composition through the inquiry button.
The manufacturer's two-page flyer (FY0002ENG rev. C), the 28-page technical brochure (rev. C, with calibration tables, dimensions, weights and Cg values) and the English User, Maintenance and Warning Manual (rev. D, edition 02/2026, 344 pages).