Pietro Fiorentini Aperflux 851 High-Medium Pressure Gas Regulator

Verified product
Brand:
Pietro Fiorentini
Product code:
100094

Aperflux 851 is Pietro Fiorentini's balanced, pilot-operated, top-entry gas pressure regulator for high-pressure transmission and medium-pressure distribution. Fail Open per EN 334, DN 25 to DN 250, inlet up to 85 barg, outlet 0.8 to 74 barg, with optional silencer, slam-shut and monitor built into the same body.

  • Accuracy class (AC)up to 2.5 (depending on working…
  • Design standard and approvalDesigned to EN 334; certified to…
  • Downstream (outlet) pressure range Wd0.08 to 7.4 MPa | 0.8 to 74 barg
Download datasheet

Overview

Product Gallery

Key Features

Pietro FiorentiniPF
  • Balanced pilot-operated design: outlet pressure is independent of…
  • True top-entry body: in-field maintenance without removing the…
  • Fail Open per EN 334, with integral SB/82 or HB/97 slam-shut and…
  • Works at low differential pressure (minimum 0.5 barg, 2 barg…
  • Seven sizes from DN 25 to DN 250 with ASME B16.5 Class 150/300/600 or…
  • Hydrogen Ready for NG-H2 blending (20% blending compatible; higher on…

Typical Applications

See all applications
  • City-gate stations in high-pressure gas transmission

    City-gate stations in high-pressure gas transmission

  • Gas compression and booster stations

    Gas compression and booster stations

  • Gas storage and regasification plants

    Gas storage and regasification plants

  • Heavy industry and large industrial gas consumers

    Heavy industry and large industrial gas consumers

Product Overview

Aperflux 851 is Pietro Fiorentini's balanced, pilot-operated, top-entry gas pressure regulator for high-pressure transmission and medium-pressure distribution. Fail Open per EN 334, DN 25 to DN 250, inlet up to 85 barg, outlet 0.8 to 74 barg, with optional silencer, slam-shut and monitor built into the same body.

The Aperflux 851 is a pilot-operated gas pressure regulator designed and manufactured by Pietro Fiorentini for previously filtered, non-corrosive gases. The manufacturer positions it mainly for high-pressure transmission systems and for medium-pressure natural gas distribution networks, and classifies it as Fail Open under EN 334: if the control loop fails, the main valve moves toward the open position, so it is normally paired with a slam-shut or an in-line monitor for overpressure protection.

Operating principle

Aperflux 851 is a balanced regulator: the controlled outlet pressure is not affected by variations in inlet pressure or flow, so a single-size orifice serves all pressure and flow conditions. Set-point adjustment is made through the pilot, which loads and unloads pressure in the upper diaphragm chamber of the main valve. The manufacturer describes a dynamic balancing system that gives a high turn-down ratio with accurate outlet-pressure control, a built-in pilot filter, and operation at low differential pressure (minimum 0.5 barg, 2 barg recommended). It is a true top-entry design: internal parts can be maintained in the field without removing the body from the pipework.

Accessories built onto the same body

  • DB/851 integral silencer for noise reduction (the manufacturer gives 85 dBA at 1 m as the recommended limit in its chart).
  • SB/82 slam-shut valve (all sizes) or HB/97 slam-shut valve (4 in to 10 in only), with over-pressure and under-pressure shut-off, internal by-pass and push-button trip test.
  • PM/819 monitor regulator integrated on the same valve body, with its own actuator, pilot and seat.
  • Opening indicator, Cg limiter, accelerator on the monitor, and pilot-circuit items such as heating cable, PPH200 heater and supplementary filter CF14.

Per the brochure, the built-in silencer, slam-shut or monitor each lower the Cg by about 5 percent compared with the plain version, and all can be retrofitted without removing the body from the line.

Supply through Barmaan

Aperflux 851 is supplied by Barmaan to order: send us the gas, the inlet pressure range, the required outlet set point, the maximum flow and the line size and flange class, and we quote the matching configuration, pilot range and accessories. Price, availability and lead time are confirmed in the quotation; this page does not publish a price. Barmaan is not presented here as a manufacturer; all technical data on this page is taken from the manufacturer's published flyer and technical brochure, which are attached below. Conformity documents for a specific project can be requested through the quotation.

Technical Specifications

AttributeValue
General
ManufacturerPietro Fiorentini S.p.A. — Arcugnano (Vicenza), Italy
TypePilot-operated, balanced gas pressure regulator (high-medium pressure)
Fail action (EN 334)Fail Open
Suitable mediaPreviously filtered, non-corrosive gases (natural gas; biomethane; NG-H2 blends)
Pressure and performance
Design pressure (PS)up to 10.2 MPa | 102 barg
Inlet pressure (MAOP)0.13 to 8.5 MPa | 1.3 to 85 barg
Downstream (outlet) pressure range Wd0.08 to 7.4 MPa | 0.8 to 74 barg
Minimum operating differential pressure0.05 MPa | 0.5 barg (recommended 0.2 MPa | 2 barg)
Accuracy class (AC)up to 2.5 (depending on working conditions)
Lock-up pressure class (SG)up to 10 (depending on working conditions)
Ambient temperature (TS)-20 °C to +60 °C
Inlet gas temperature-20 °C to +60 °C
Flow coefficient Cg by size (DN)DN 25: 480; DN 50: 1550; DN 80: 3790; DN 100: 5554; DN 150: 11112; DN 200: 17316; DN 250: 24548
Form factor K1113.9
Main pilot models and setting ranges302/A: 0.8 to 9.5 barg; 304/A: 7 to 43 barg; 305/A: 20 to 60 barg; 307/A: 41 to 74 barg
Pilot setting options/A manual; /D electric remote; /CS pneumatic remote; /FIO smart unit (remote setting, monitoring, flow limitation)
Construction and sizes
Nominal sizesDN 25 | 1 in; DN 50 | 2 in; DN 80 | 3 in; DN 100 | 4 in; DN 150 | 6 in; DN 200 | 8 in; DN 250 | 10 in
End connectionsASME B16.5 Class 150/300/600 RF or RTJ; ISO 7005 PN 16/25/40
BodyCast steel ASTM A352 LCC (Class 300 and 600); ASTM A216 WCB (Class 150 and PN 16); cover in rolled or forged carbon steel
SeatStainless steel for DN ≤ 3 in; carbon steel with stainless-steel seal edge for 4 in and above
DiaphragmVulcanized rubber (sealing ring: nitrile rubber)
Available accessoriesDB/851 silencer; SB/82 slam-shut; HB/97 slam-shut; PM/819 monitor; opening indicator
Weight (standard version, by size)ANSI 300: 21 / 36 / 82 / 128 / 257 / 395 / 750 kg (DN 25 / 50 / 80 / 100 / 150 / 200 / 250)
Face-to-face length (by size)ANSI 300: 197 / 267 / 317 / 368 / 473 / 568 / 708 mm (DN 25 to DN 250)
Standards and compliance
Design standard and approvalDesigned to EN 334; certified to Directive 2014/68/EU (PED), CE
Leakage classBubble-tight, better than Class VIII to ANSI/FCI 70-3
Hydrogen / biomethaneHydrogen Ready for NG-H2 blending; biomethane compatible; 20% hydrogen blending compatible, higher blending available on request
View full specifications (PDF)

Orderable Models

Sister models of this family — informational, not stock.

Model codeDescriptionMeasuring range
302/AMain pilot 302/AManual-setting main pilot; the manufacturer also lists /D electric, /CS pneumatic and /FIO smart remote-setting versions.0.08 - 0.95 MPa (0.8 - 9.5 barg)
304/AMain pilot 304/AManual-setting main pilot; the manufacturer also lists /D electric, /CS pneumatic and /FIO smart remote-setting versions.0.7 - 4.3 MPa (7 - 43 barg)
305/AMain pilot 305/AManual-setting main pilot; the manufacturer also lists /D electric, /CS pneumatic and /FIO smart remote-setting versions.2 - 6 MPa (20 - 60 barg)
307/AMain pilot 307/AManual-setting main pilot; the manufacturer also lists /D electric, /CS pneumatic and /FIO smart remote-setting versions.4.1 - 7.4 MPa (41 - 74 barg)

All listed models can be supplied with your required certification, output protocol and process connection — contact us or request a quote for exact model-code selection.

Downloads & Documentation

Applications & Industries

  • City-gate stations in high-pressure gas transmission

    City-gate stations in high-pressure gas transmission

  • Gas compression and booster stations

    Gas compression and booster stations

  • Gas storage and regasification plants

    Gas storage and regasification plants

  • Heavy industry and large industrial gas consumers

    Heavy industry and large industrial gas consumers

  • Gas liquefaction facilities and medium-pressure…

    Gas liquefaction facilities and medium-pressure…

Reviews

No reviews yet

Be the first to review this product.

Frequently Asked Questions

What does Fail Open mean for the Aperflux 851?

Under EN 334 the Aperflux 851 is classified as Fail Open: if the loading pressure or the pilot circuit fails, the main valve tends to move to the open position. For this reason the manufacturer offers the SB/82 or HB/97 slam-shut and the PM/819 monitor on the same body. Which protection is required is decided by your station design and the applicable code.

What pressures and sizes does it cover?

Design pressure up to 102 barg, inlet pressure (MAOP) from 1.3 to 85 barg, outlet pressure from 0.8 to 74 barg, in sizes DN 25 (1 in), 50, 80, 100, 150, 200 and DN 250 (10 in). The main pilot models are 302/A (0.8 to 9.5 barg), 304/A (7 to 43 barg), 305/A (20 to 60 barg) and 307/A (41 to 74 barg). Accuracy class is up to 2.5 and lock-up class up to 10, depending on working conditions.

Can it handle hydrogen blends and biomethane?

The manufacturer states that the Aperflux 851 is Hydrogen Ready for NG-H2 blending, biomethane compatible and compatible with 20% hydrogen blending, with higher blending available on request. If your project involves a higher hydrogen content, state the percentage in your inquiry so the configuration can be confirmed with the manufacturer.

Do you publish a price for the Aperflux 851?

No. The price depends on size, flange class, pilot range, accessories and quantity, so it is given in a quotation. Send the line size, inlet and outlet pressures, maximum flow and gas composition through the inquiry button.

Which documents are attached to this page?

The manufacturer's two-page flyer (FY0002ENG rev. C), the 28-page technical brochure (rev. C, with calibration tables, dimensions, weights and Cg values) and the English User, Maintenance and Warning Manual (rev. D, edition 02/2026, 344 pages).

Related Products

Pietro Fiorentini ASX 176 High-Medium Pressure Gas Regulator — official manufacturer photo

Pietro FiorentiniASX 176

High-medium pressure gas regulator

Price on request

Pietro Fiorentini ASX 176/FO High-Medium Pressure Gas Regulator — official manufacturer photo

Pietro FiorentiniASX 176/FO

High-medium pressure gas regulator

Price on request

Pietro Fiorentini Dixi AP High-Medium Pressure Gas Regulator — official manufacturer photo

Pietro FiorentiniDixi AP High-Medium Pressure Gas Regulator DN25

Gas Pressure Regulators

Price on request