Endress+HauserProline Promag W 800
Electromagnetic flowmeter
LTE Cat M1, Cat NB1, Cat NB2, GPRS, EGPRS; Modbus RS485; 3x…

The Promag W 400 is the versatile standard electromagnetic flowmeter for the water and wastewater industry, measuring reliably at constant accuracy with a 0 x DN inlet run and no pressure loss.
Price
Out of stock — request a quote to sourceSubmit a quote request to get pricing.






Drinking water, utility water and industrial or municipal…

Drinking-water distribution networks and utilities.

Water custody-transfer points approved to MI-001 / OIML R49.

Industrial process liquids, slurries and chemical lines…
The Promag W 400 is the versatile standard electromagnetic flowmeter for the water and wastewater industry, measuring reliably at constant accuracy with a 0 x DN inlet run and no pressure loss.
Endress+Hauser Proline Promag W 400 Electromagnetic Flowmeter: The Promag W 400 is the versatile standard electromagnetic flowmeter for the water and wastewater industry, measuring reliably at constant accuracy with a 0 x DN inlet run and no pressure loss.
An electromagnetic flowmeter applies Faraday's law: a magnetic field is generated across the pipe, and an electrically conductive liquid moving through it induces a voltage proportional to the flow velocity, picked up by electrodes. The measuring tube has no constriction and no moving parts, so there is no pressure loss from the sensor and virtually no wear. According to the manufacturer, the bidirectional principle is virtually independent of pressure, density, temperature and viscosity.
Sensor protection to IP68 (Type 6P) with EN ISO 12944 corrosion protection for underground or underwater use, drinking-water approvals and custody-transfer approval to MI-001 / OIML R49. Key figures from the official data: nominal diameter DN 25–3000; maximum measured error ±0.5 % o.r. ± 1 mm/s; measuring range 0.5–263 000 m³/h; medium temperature 0…+90 °C; process pressure up to PN 40 / Class 300 / 20K.
Barmaan supplies this model by order code on inquiry; there is no list price on the page. Send the nominal diameter, medium, process connection and the required outputs, and we will confirm the configuration against the official Technical Information.
| Attribute | Value |
|---|---|
| General | |
| Measuring principle | Electromagnetic (Faraday) |
| Nominal diameter range | DN 25 to 3000 (1 to 120") |
| Measured variables | Volume flow, conductivity, mass flow |
| Degree of protection | Compact: IP66/67, type 4X; remote sensor option: IP68, type 6P |
| Approvals and certificates | Drinking water: ACS, KTW-BWGL, NSF 61, WRAS BS 6920; custody transfer MI-001 / OIML R49; cCSAus; CRN |
| Official document | Technical Information TI01046D |
| Performance & accuracy | |
| Maximum measured error | Volume flow: ±0.5 % o.r. ± 1 mm/s (standard); ±0.2 % o.r. ± 2 mm/s (option, Flat Spec) |
| Measuring range | 0.5 m³/h to 263 000 m³/h (2.5 gal/min to 1665 Mgal/d) |
| Process conditions | |
| Medium temperature range | Hard rubber: 0 to +80 °C; polyurethane: –20 to +50 °C; PTFE: –20 to +90 °C |
| Maximum process pressure | PN 40, Class 300, 20K |
| Wetted materials | Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum |
| Electrical & communication | |
| Digital communication | HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART output, pulse/frequency/switch output |
| Power supply | AC 100…240 V / AC/DC 24 V |

Drinking water, utility water and industrial or municipal…

Drinking-water distribution networks and utilities.

Water custody-transfer points approved to MI-001 / OIML R49.

Industrial process liquids, slurries and chemical lines…
No reviews yet
Be the first to review this product.
Electrically conductive liquids, e.g. water, wastewater and many process liquids. It cannot measure non-conductive liquids such as pure hydrocarbons or gases.
No. The measuring tube has no cross-section constriction, so the sensor itself causes no pressure loss, and it has no moving parts to maintain.
The approvals differ per model and liner; the model-specific drinking-water or hygienic approvals the manufacturer lists are in the specification table and the Technical Information.
Hard rubber (0 to +80 °C), polyurethane (–20 to +50 °C) and PTFE (–20 to +90 °C), with 1.4435 (316L), Alloy C22 or tantalum electrodes.
The official Endress+Hauser Technical Information TI01046D is attached in the downloads section of this page, so you have the full specification and ordering information.
Pricing depends on nominal diameter, process connection, materials, approvals and the transmitter configuration (order code). Send us your requirements and we quote it on request.

Electromagnetic flowmeter
LTE Cat M1, Cat NB1, Cat NB2, GPRS, EGPRS; Modbus RS485; 3x…

Electromagnetic flowmeter
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Electromagnetic flowmeter
HART, Modbus RS485, IO-Link; 4–20 mA; pulse/frequency/switch…

Coriolis flowmeter
4–20 mA HART + Pulse/Frequency (I-OUT, f-OUT)
Ships in 1 day
from $4,000

Energy meter + ultraflow flow sensor
M-Bus, wireless M-Bus, Modbus, BACnet, LoRa … (2 module slots)

Coriolis flowmeter
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Ultrasonic clamp-on flowmeter

Coriolis flowmeter
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Coriolis flowmeter
Calibration, testing and supply services for this equipment