Endress+HauserProline Promag W 400
Electromagnetic flowmeter
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

The Promass X 300 is the highest-capacity four-tube Coriolis flowmeter of the range, built for the highest flow rates and for on- and offshore oil and gas applications.
Price
Out of stock — request a quote to sourceSubmit a quote request to get pricing.





Oil and gas: on- and offshore transfer, loading and…

Custody transfer and high-accuracy measurement of liquids…

Chemical and petrochemical processes: dosing, blending and…
The Promass X 300 is the highest-capacity four-tube Coriolis flowmeter of the range, built for the highest flow rates and for on- and offshore oil and gas applications.
Endress+Hauser Proline Promass X 300 Coriolis Flowmeter: The Promass X 300 is the highest-capacity four-tube Coriolis flowmeter of the range, built for the highest flow rates and for on- and offshore oil and gas applications.
A Coriolis flowmeter measures mass flow directly: the measuring tubes are set into vibration, the flowing medium changes that vibration, and the transmitter evaluates the change as mass flow. The same sensor also delivers density and temperature, from which volume flow and concentration can be derived. According to the manufacturer, the principle works independently of physical fluid properties such as viscosity or density.
A single installation point delivers premium accuracy for large quantities; the four-tube system has low pressure drop and the whole exterior is made of 1.4435 (316L). Key figures from the official data: nominal diameter DN 300–400; maximum measured error ±0.10 %; measuring range 0–4100 t/h; medium temperature –50…+180 °C; process pressure up to PN 100 / Class 600.
Barmaan supplies this model by order code on inquiry; there is no list price on the page. Send the nominal diameter, medium, process connection and the required outputs, and we will confirm the configuration against the official Technical Information.
| Attribute | Value |
|---|---|
| General | |
| Measuring principle | Coriolis, four-tube system |
| Nominal diameter range | DN 300 to 400 (12 to 16") |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
| Degree of protection | IP66/67, type 4X enclosure |
| Approvals and certificates | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC; functional safety per IEC 61508 |
| Official document | Technical Information TI01279D |
| Performance & accuracy | |
| Maximum measured error | Mass flow (liquid): ±0.10 % (standard), ±0.05 % (option); volume flow (liquid): ±0.10 %; mass flow (gas): ±0.25 %; density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 4100 t/h (0 to 4520 tn. sh./h) |
| Process conditions | |
| Medium temperature range | –50 to +180 °C (–58 to +356 °F) |
| Maximum process pressure | PN 100, Class 600 |
| Wetted materials | Measuring tube and connection: 1.4404 (316/316L); exterior 1.4435 (316L) |
| Electrical & communication | |
| Digital communication | HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus TCP over Ethernet-APL, PROFINET, EtherNet/IP, OPC-UA |

Oil and gas: on- and offshore transfer, loading and…

Custody transfer and high-accuracy measurement of liquids…

Chemical and petrochemical processes: dosing, blending and…
No reviews yet
Be the first to review this product.
It measures mass flow directly, together with density and temperature; volume flow, corrected volume flow and concentration are derived from these.
According to the manufacturer, the measuring principle operates independently of physical fluid properties such as viscosity or density.
The Technical Information lists "no in-/outlet run needs" as a benefit of the Promass 300 family, which saves installation space.
The measuring range is 0 to 4100 t/h for nominal diameters DN 300 to 400 (12 to 16"), at a maximum process pressure of PN 100 / Class 600.
The official Endress+Hauser Technical Information TI01279D is attached in the downloads section of this page, so you have the full specification and ordering information.
Pricing depends on nominal diameter, process connection, materials, approvals and the transmitter configuration (order code). Send us your requirements and we quote it on request.

Electromagnetic flowmeter
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

Electromagnetic flowmeter
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Electromagnetic flowmeter
HART, Modbus RS485, IO-Link; 4–20 mA; pulse/frequency/switch…

Coriolis flowmeter
4–20 mA HART + Pulse/Frequency (I-OUT, f-OUT)
Ships in 1 day
from $4,000

Energy meter + ultraflow flow sensor
M-Bus, wireless M-Bus, Modbus, BACnet, LoRa … (2 module slots)

Electromagnetic flowmeter
LTE Cat M1, Cat NB1, Cat NB2, GPRS, EGPRS; Modbus RS485; 3x…

Ultrasonic clamp-on flowmeter

Coriolis flowmeter

Coriolis flowmeter
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…
Calibration, testing and supply services for this equipment