Skip to content
Barmaan Trading Company
Flow Meters

Endress+Hauser Proline Promass X 300 Coriolis Flowmeter

Verified product
Brand:
Endress+Hauser
Product code:
100104

The Promass X 300 is the highest-capacity four-tube Coriolis flowmeter of the range, built for the highest flow rates and for on- and offshore oil and gas applications.

  • Digital communicationHART, PROFIBUS DP/PA, FOUNDATION…
  • Approvals and certificatesATEX, IECEx, cCSAus, NEPSI, INMETRO…
  • Measuring principleCoriolis, four-tube system
Download datasheet

Overview

Product Gallery

Key Features

Endress+HauserEH
  • Multivariable measurement: mass flow, density and temperature from…
  • Space-saving installation: no in- or outlet run requirements are…
  • Proline 300 transmitter: compact dual-compartment housing with up to…
  • Integrated verification with Heartbeat Technology, with traceability…
  • A single installation point delivers premium accuracy for large…

Typical Applications

See all applications
  • Oil and gas: on- and offshore transfer, loading and…

    Oil and gas: on- and offshore transfer, loading and…

  • Custody transfer and high-accuracy measurement of liquids…

    Custody transfer and high-accuracy measurement of liquids…

  • Chemical and petrochemical processes: dosing, blending and…

    Chemical and petrochemical processes: dosing, blending and…

Product Overview

The Promass X 300 is the highest-capacity four-tube Coriolis flowmeter of the range, built for the highest flow rates and for on- and offshore oil and gas applications.

Endress+Hauser Proline Promass X 300 Coriolis Flowmeter: The Promass X 300 is the highest-capacity four-tube Coriolis flowmeter of the range, built for the highest flow rates and for on- and offshore oil and gas applications.

A Coriolis flowmeter measures mass flow directly: the measuring tubes are set into vibration, the flowing medium changes that vibration, and the transmitter evaluates the change as mass flow. The same sensor also delivers density and temperature, from which volume flow and concentration can be derived. According to the manufacturer, the principle works independently of physical fluid properties such as viscosity or density.

A single installation point delivers premium accuracy for large quantities; the four-tube system has low pressure drop and the whole exterior is made of 1.4435 (316L). Key figures from the official data: nominal diameter DN 300–400; maximum measured error ±0.10 %; measuring range 0–4100 t/h; medium temperature –50…+180 °C; process pressure up to PN 100 / Class 600.

Barmaan supplies this model by order code on inquiry; there is no list price on the page. Send the nominal diameter, medium, process connection and the required outputs, and we will confirm the configuration against the official Technical Information.

Technical Specifications

AttributeValue
General
Measuring principleCoriolis, four-tube system
Nominal diameter rangeDN 300 to 400 (12 to 16")
Measured variablesMass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
Degree of protectionIP66/67, type 4X enclosure
Approvals and certificatesATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC; functional safety per IEC 61508
Official documentTechnical Information TI01279D
Performance & accuracy
Maximum measured errorMass flow (liquid): ±0.10 % (standard), ±0.05 % (option); volume flow (liquid): ±0.10 %; mass flow (gas): ±0.25 %; density (liquid): ±0.0005 g/cm³
Measuring range0 to 4100 t/h (0 to 4520 tn. sh./h)
Process conditions
Medium temperature range–50 to +180 °C (–58 to +356 °F)
Maximum process pressurePN 100, Class 600
Wetted materialsMeasuring tube and connection: 1.4404 (316/316L); exterior 1.4435 (316L)
Electrical & communication
Digital communicationHART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus TCP over Ethernet-APL, PROFINET, EtherNet/IP, OPC-UA
View full specifications (PDF)

Downloads & Documentation

Applications & Industries

  • Oil and gas: on- and offshore transfer, loading and…

    Oil and gas: on- and offshore transfer, loading and…

  • Custody transfer and high-accuracy measurement of liquids…

    Custody transfer and high-accuracy measurement of liquids…

  • Chemical and petrochemical processes: dosing, blending and…

    Chemical and petrochemical processes: dosing, blending and…

Reviews

No reviews yet

Be the first to review this product.

Frequently Asked Questions

What does a Coriolis flowmeter measure?

It measures mass flow directly, together with density and temperature; volume flow, corrected volume flow and concentration are derived from these.

Does viscosity or density of the fluid affect the reading?

According to the manufacturer, the measuring principle operates independently of physical fluid properties such as viscosity or density.

Are inlet and outlet runs required?

The Technical Information lists "no in-/outlet run needs" as a benefit of the Promass 300 family, which saves installation space.

What flow rates does the Promass X 300 cover?

The measuring range is 0 to 4100 t/h for nominal diameters DN 300 to 400 (12 to 16"), at a maximum process pressure of PN 100 / Class 600.

Where can I find the official catalog and datasheet?

The official Endress+Hauser Technical Information TI01279D is attached in the downloads section of this page, so you have the full specification and ordering information.

How do I get a price?

Pricing depends on nominal diameter, process connection, materials, approvals and the transmitter configuration (order code). Send us your requirements and we quote it on request.

Why buy inspected stock from Barmaan

  • Inspected and tested before dispatch
  • 30-day functional warranty
  • Authenticity checked against nameplate and order code
  • Sourced to order — lead time confirmed in your quote
  • Delivery to the project site
  • After-sales support
Ask on WhatsApp+964 751 113 9532

Related Products

Out of stock
Endress+Hauser Proline Promag W 400 Electromagnetic Flowmeter — official manufacturer photo

Endress+HauserProline Promag W 400

Electromagnetic flowmeter

HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

Out of stock
Endress+Hauser Proline Promag H 300 Electromagnetic Flowmeter — official manufacturer photo

Endress+HauserProline Promag H 300

Electromagnetic flowmeter

HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Out of stock
Endress+Hauser Proline Promag D 10 Electromagnetic Flowmeter — official manufacturer photo

Endress+HauserProline Promag D 10

Electromagnetic flowmeter

HART, Modbus RS485, IO-Link; 4–20 mA; pulse/frequency/switch…

View all Flow Meters
Used3 units
Endress+Hauser Promass 83F DN50 Coriolis flowmeter (unit 1, order 83F50-1FU0/0, PN40), full view

Endress+HauserPromass 83F DN50

Coriolis flowmeter

4–20 mA HART + Pulse/Frequency (I-OUT, f-OUT)

Ships in 1 day

from $4,000

Out of stock
Kamstrup MULTICAL 603 energy meter set: ULTRAFLOW flow tube, calculator and Pt500 sensors

KamstrupMULTICAL 603

Energy meter + ultraflow flow sensor

M-Bus, wireless M-Bus, Modbus, BACnet, LoRa … (2 module slots)

Out of stock
Endress+Hauser Proline Promag W 800 Electromagnetic Flowmeter — official manufacturer photo

Endress+HauserProline Promag W 800

Electromagnetic flowmeter

LTE Cat M1, Cat NB1, Cat NB2, GPRS, EGPRS; Modbus RS485; 3x…

Out of stock
Endress+Hauser Proline Prosonic Flow W 400 Ultrasonic Clamp-on Flowmeter — official manufacturer photo

Endress+HauserProline Prosonic Flow W 400

Ultrasonic clamp-on flowmeter

Out of stock
Endress+Hauser Proline Promass Q 300 Coriolis Flowmeter — official manufacturer photo

Endress+HauserProline Promass Q 300

Coriolis flowmeter

Out of stock
Endress+Hauser Proline Promass P 300 Coriolis Flowmeter — official manufacturer photo

Endress+HauserProline Promass P 300

Coriolis flowmeter

HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Calibration, testing and supply services for this equipment