
Endress+HauserProline Promag W 400
Electromagnetic flowmeter
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

The Prowirl F 200 is the flanged member of the Proline Prowirl 200 vortex family, described by the manufacturer as suitable for a wide range of applications and optimized for steam.
Price
Out of stock — request a quote to sourceSubmit a quote request to get pricing.




Steam metering and energy balancing for boilers, headers…

Liquids in chemical, petrochemical and general process…
Gases and compressed air in utility and process lines.
Cryogenic media, with the high/low temperature option from…
The Prowirl F 200 is the flanged member of the Proline Prowirl 200 vortex family, described by the manufacturer as suitable for a wide range of applications and optimized for steam.
Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter: The Prowirl F 200 is the flanged member of the Proline Prowirl 200 vortex family, described by the manufacturer as suitable for a wide range of applications and optimized for steam.
A vortex flowmeter places a bluff body in the flow; behind it vortices shed alternately (Karman vortex street), and their frequency is proportional to the flow velocity. The sensor detects these pressure oscillations and the transmitter converts them to volume flow, and with temperature measurement to mass or energy flow. It is a preferred principle for wet, saturated and superheated steam, gases and liquids, including cryogenic media.
Wet steam detection is available on the mass-flow sensor version (nominal diameters DN 25 to 100 per the Technical Information). Key figures from the official data: nominal diameter DN 15–300; maximum measured error ±0.75 % … ±1.00 %; measuring range 0.16–2412 m³/h; medium temperature –40…+260 °C; process pressure up to PN 40 / Class 300 / 20K.
Barmaan supplies this model by order code on inquiry; there is no list price on the page. Send the nominal diameter, medium, process connection and the required outputs, and we will confirm the configuration against the official Technical Information.
| Attribute | Value |
|---|---|
| General | |
| Measuring principle | Vortex (Karman vortex street), DSC sensor |
| Nominal diameter range | DN 15 to 300 (½ to 12") |
| Degree of protection | IP66/67, type 4X enclosure |
| Approvals and certificates | ATEX, IECEx, cCSAus, EAC; functional safety per IEC 61508; PED, CRN, AD 2000 |
| Official document | Technical Information TI01084D |
| Performance & accuracy | |
| Maximum measured error | Volume flow: ±0.75 % (liquid), ±1.00 % (steam, gas); mass flow: ±0.85 % (liquid), ±1.7 % (steam, gas) |
| Measuring range | Liquid: 0.16 to 2412 m³/h; steam, gas: 2 to 32 166 m³/h (depending on medium) |
| Process conditions | |
| Medium temperature range | Standard: –40 to +260 °C; high/low temperature option: –200 to +400 °C |
| Maximum process pressure | PN 40, Class 300, 20K |
| Wetted materials | Measuring tube: 1.4408 (CF3M); DSC sensor: 1.4435 (316/316L) |
| Electrical & communication | |
| Digital communication | 4–20 mA HART; PROFIBUS PA; FOUNDATION Fieldbus; pulse/frequency/switch output |
| Power supply | DC 12 to 35 V (4–20 mA HART) |

Steam metering and energy balancing for boilers, headers…
Gases and compressed air in utility and process lines.

Liquids in chemical, petrochemical and general process…
Cryogenic media, with the high/low temperature option from…
No reviews yet
Be the first to review this product.
The Technical Information names wet, saturated and superheated steam, gases and liquids, including cryogenic media, as the preferred applications.
4–20 mA HART, PROFIBUS PA and FOUNDATION Fieldbus, plus pulse/frequency/switch output and a 4–20 mA current input.
The manufacturer lists ATEX, IECEx, cCSAus and EAC approvals and functional safety per IEC 61508; confirm the approval of your exact order code in the Technical Information.
The Technical Information describes a Wet Steam Detection option for the mass-flow version with integrated temperature measurement, DN 25 to 100 (1 to 4"). Check the order code for availability.
The official Endress+Hauser Technical Information TI01084D is attached in the downloads section of this page, so you have the full specification and ordering information.
Pricing depends on nominal diameter, process connection, materials, approvals and the transmitter configuration (order code). Send us your requirements and we quote it on request.

Electromagnetic flowmeter
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

Electromagnetic flowmeter
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Electromagnetic flowmeter
HART, Modbus RS485, IO-Link; 4–20 mA; pulse/frequency/switch…

Coriolis flowmeter
4–20 mA HART + Pulse/Frequency (I-OUT, f-OUT)
Ships in 1 day
from $4,000

Energy meter + ultraflow flow sensor
M-Bus, wireless M-Bus, Modbus, BACnet, LoRa … (2 module slots)

Electromagnetic flowmeter
LTE Cat M1, Cat NB1, Cat NB2, GPRS, EGPRS; Modbus RS485; 3x…

Coriolis flowmeter
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Coriolis flowmeter

Coriolis flowmeter
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…
Calibration, testing and supply services for this equipment