Endress+HauserProline Promag W 400
Electromagnetic flowmeter
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…
1 / 2Yokogawa VY Series vortex flowmeter, successor to the YEWFLO line: liquids, gas and steam, ±0.75 % (liquid) / ±1 % (gas, steam) of reading, -196 to +440 °C, sizes 15 to 400 mm, flanges up to ASME Class 1500, HART 7, FOUNDATION Fieldbus or Modbus. Catalog model; supply on inquiry.
Price
Out of stock — request a quote to sourceSubmit a quote request to get pricing.





Saturated and superheated steam metering in power plants…

Process gases and compressed air, natural gas and…

Clean liquids in oil and gas, petrochemical and chemical…
Cryogenic and high-temperature process lines within -196 to…
Yokogawa VY Series vortex flowmeter, successor to the YEWFLO line: liquids, gas and steam, ±0.75 % (liquid) / ±1 % (gas, steam) of reading, -196 to +440 °C, sizes 15 to 400 mm, flanges up to ASME Class 1500, HART 7, FOUNDATION Fieldbus or Modbus. Catalog model; supply on inquiry.
The Yokogawa VY Series is the current generation of Yokogawa vortex flowmeters, succeeding the YEWFLO line (including digitalYEWFLO). It measures the flow rate of liquids, gases and saturated or superheated steam by sensing the Karman vortex street that forms behind the shedder bar. Yokogawa's integral detection structure — a signal-sensing element inside the shedder bar and a design with no moving parts — is carried over from YEWFLO, and the optimized SSP (Yokogawa's digital signal processing) filtering makes readings steadier and more resistant to vibration.
The General Specifications quote an accuracy of ±0.75 % of reading for liquids and ±1 % of reading for gas and steam, with ±0.2 % repeatability. The line covers sizes VY015 to VY400 (15 to 400 mm), a fluid temperature range of -196 to +440 °C including the integral flowmeter, flange ratings up to ASME Class 1500, general, reduced-bore, high-pressure reduced-bore and dual-sensor (welded) bodies, and a built-in temperature sensor option for mass and heat-flow calculation. Outputs are 4–20 mA (two-wire) with HART 7, a transistor contact output (pulse, alarm or status), and FOUNDATION Fieldbus or Modbus communication types. A health-diagnosis function records the status of the whole instrument so that cleaning or shedder-bar replacement can be planned from condition; SIL 2 and NAMUR options are listed.
This page documents the catalog model from the official Yokogawa General Specifications GS 01F07A00-01EN (9th edition, 31 March 2026), attached for download. Size, body type, materials, process connection, transmitter and approvals are fixed by the model and suffix code at ordering. Barmaan supplies the model on inquiry and shows no price here: send the fluid, flow range, line size, temperature and pressure and the output you need, and we reply with availability and a quotation.
| Attribute | Value |
|---|---|
| General | |
| Manufacturer / series | Yokogawa Electric Corporation (Japan) — VY Series vortex flowmeter, successor to YEWFLO |
| Measuring principle | Vortex shedding (Karman vortex street) with SSP digital signal processing |
| Measured fluids | Liquid, gas, saturated steam, superheated steam (avoid multiphase, sticky or corrosive fluids) |
| Performance & accuracy | |
| Accuracy | ±0.75 % of reading (liquid); ±1 % of reading (gas, steam) |
| Repeatability | ±0.2 % of reading |
| Process conditions & connection | |
| Sizes | VY015 to VY400 (15 to 400 mm) |
| Process temperature | -196 to +440 °C (T1 class, 438 °C with built-in temperature sensor); T6 to T1 classes available |
| Ambient temperature | -50 to +60 °C (integral flowmeter, remote transmitter); remote sensor T6/T80: -50 to +40 °C |
| Flange / connection | Flange and wafer types; flange ratings up to ASME Class 1500 |
| Construction & materials | |
| Body types | General type, reduced bore (1 or 2 sizes), high-pressure reduced bore (1 size), dual-sensor (welded) general type |
| Wetted materials | Body CF8M stainless steel (or F316, nickel alloy CW-12MW); shedder bar duplex stainless steel S31803 / 1.4517, CF8M or nickel alloy N10276 / CW-12MW |
| Degree of protection | IP66/IP67 (IEC 60529); housing: low-copper aluminium alloy |
| Power & output | |
| Output signal | 4–20 mA DC two-wire (±0.1 % of span) and transistor contact output (pulse, alarm or status, 10.5–30 V DC, 80 mA) |
| Communication | HART 7, FOUNDATION Fieldbus (9–32 V DC), Modbus (9–30 V DC) |
| Approvals & safety | |
| Safety and approvals | SIL 2 and NAMUR options listed; PED data per model (PS 41.4 MPa for VY015–VY300, 25 MPa for VY400) |
Sister models of this family — informational, not stock.
| Model code | Description | Measuring range |
|---|---|---|
| VY-GENERAL | VY general typeStandard flanged or wafer body, sizes VY015 to VY400. | 15–400 mm |
| VY-RB | VY reduced bore (1 or 2 sizes)Smaller meter bore than the line to raise velocity and extend the low-flow range; high-pressure reduced bore (1 size) available. | — |
| VY-DS | VY dual-sensor (welded) general typeDual-sensor welded body covered by GS 01F07A00-01EN. | — |
All listed models can be supplied with your required certification, output protocol and process connection — contact us or request a quote for exact model-code selection.

Saturated and superheated steam metering in power plants…

Process gases and compressed air, natural gas and…

Clean liquids in oil and gas, petrochemical and chemical…
Cryogenic and high-temperature process lines within -196 to…
No reviews yet
Be the first to review this product.
No. The VY Series is the newer generation that succeeds the YEWFLO line (digitalYEWFLO DY is the previous model, documented in GS 01F06A00-01EN). This page documents the VY Series from GS 01F07A00-01EN; match the nameplate before ordering parts or spares.
This is a catalog model documented from the manufacturer's specifications. Availability, condition and lead time are confirmed per inquiry, and no price is published on this page.
Yes. The General Specifications list saturated and superheated steam among the measured fluids, with ±1 % of reading accuracy for gas and steam. A built-in temperature sensor option supports mass and heat-flow calculation.
Yokogawa General Specifications GS 01F07A00-01EN (VY Series, 9th edition, 31 March 2026), attached as a PDF on this page.

Electromagnetic flowmeter
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485; 0/4–20 mA HART…

Electromagnetic flowmeter
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Electromagnetic flowmeter
HART, Modbus RS485, IO-Link; 4–20 mA; pulse/frequency/switch…

Coriolis flowmeter
4–20 mA HART + Pulse/Frequency (I-OUT, f-OUT)
Ships in 1 day
from $4,000

Energy meter + ultraflow flow sensor
M-Bus, wireless M-Bus, Modbus, BACnet, LoRa … (2 module slots)

Electromagnetic flowmeter
LTE Cat M1, Cat NB1, Cat NB2, GPRS, EGPRS; Modbus RS485; 3x…

Coriolis flowmeter
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…

Coriolis flowmeter

Coriolis flowmeter
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, Modbus…
Calibration, testing and supply services for this equipment